ML20005B753

From kanterella
Jump to navigation Jump to search
Ltr Contract NRC-05-81-247: Independent Assessment: Destructive Testing & Analysis, (Task Orders 1-6),awarded to Franklin Inst
ML20005B753
Person / Time
Issue date: 07/30/1981
From: Morton K
NRC OFFICE OF ADMINISTRATION (ADM)
To: Joanne Stover
FRANKLIN INSTITUTE
Shared Package
ML20005B749 List:
References
CON-FIN-B-1278, CON-NRC-05-81-247, CON-NRC-5-81-247 NUDOCS 8109020081
Download: ML20005B753 (14)


Text

I,,

,m.,

ur."1::,: 1 ;, : i L'UC L E t.! IM C U ' ' ' ' " " ' ' " ' ' " ' c ! %'

i, c w['

s:n,m uu>:. a e s.

s wi$h / !

y u.m..~.

JUL 3 01981 The Franklin Institute ATTN: Mr. John R. Stover Vice President Franklin Research Center 20th and Benjamin Franklin Parkway Philadelphia, PA 19103 Gentlemen:

Subject:

Contract No. NRC-05-81-247, Task Order Nos. 1, 2, 3, 4, 5, and 6 Pursuant to the pertinent provisions of this Contract, I hereby authorize the expenditure of funds in the amount of $125,000.00 to provide to the Office of Inspection and Enforcement independent assessments, including destructive testing and analysis, of samples from NRC licensees' facilities as outlined in the enclosed Task Order Nos.1, 2, 3, 4, 5, and 6, and as further described by individual Task Authorization Forms (TAF) or other written directives issued hereunder.

The total ceiling price for all of the task orders is $125,000.00, and all activities in all disciplines hereunder shall cease when this level is reached unless otherwise notified by written order from the Contracting Officer. The amount of expenditure under each task order shall be deter-mined by the numbers of Task Authorization Form requests received per

~

task order.

This letter, executed on behalf of the Commission, is forwarded to you in quadruplicate.

Please acknowledge receipt on three (3) copies hereon, and return them to me as soon as possible.

The fourth copy is for your reten-tion.

Sincerely,

(

o AMv Kellogg V Morton ContractindOfficer Research Contracts Branch Divi., ion of Contracts 0.ffice of Administ:ation

Enclosures:

Task Order Nos. 1, 2, 3, 4, 5, and 6 (4 copies) 8109020081 810804 PDR CONTR NRC-05-81-247 PDR

JtJ!. 3 01981,

The Franklin Institute Task Order Nos. 1, 2, 3, 4, 5, and 6 RECEIVED:

Franklin Research Center h.

p,/ UM, BY:

E. B. RdsenMrE

[

TITLE:

contracts Manager DATE:

August 4, 1981 e

l l

i i

Franklin Research Center NRC Contract No. NRC-05-81-247 Task Order No.1 Civil Engineering 1.

Scope of Work a.

Provide chemical and physical tests and analysis of materials and systems used in the discipline of civil engineering.

2.

Objective of Work To provide independent technical data, records and technical assistance from field or laboratory test results.

To assist in investigations by analysis and evaluation of technical data submitted as a result of incidents and/or inspection support.

3.

Statement of Work Each sample or group of samples provided to Franklin Research Center for testing and/or analysis will carry a Task Authorization Form (TAF) which identifies the specific request including applicable codes and standards. The following items are examples of requests which may be submitted under this Task Order:

a.

Chemical and Physical Test and Analysis of Materials used in Concrete.

b.

Concrete Compression Tests.

c.

Strength Tests on Mechanical and Butt Welded Rebar Splices.

d.

Sensitization Tests of Stainless Steel Materials.

4.

Reporting Requirements Test results, analysis of material and/or the results of independent evaluation with the task order report shall be submitted to the TAF initiating office as indicated on the TAF.

A copy of~each report shall be submitted to the Project Officer:

W. Laudan, Office of s

Inspection and Enforcement:

Division of Resident and Regional Reactor Inspection, U. S. Nuclear Regulatory Commissien, MS-EW 359, Washington, D.C., 20555.

A monthly report combining activities-under all Task Orders issued will be submitted to the Contracting Officer with a copy to the Project Officer.

I 5.

Desired Completion Date In many instances time is of the essence and test results, analysis of material or results of independent evaluation are needed at the carliest turn around time possible, without the use of overtime or night differential.

In instances where more time is available, this will be indicated:on the-4 Test Authorization Form (TAF).

6.

Special Instructions or Requirements Special Instructions pertaining to the service or the follow-up report, such as proprietary information, will be made part of the TAF, or be sent by separate letter or memorandum. ' Some information provided may be used as evidence during testimony in public hearings, and in such case will be made part of the TAF or submitted by separate letter.

7.

Place of Work The majority of work under this task order will be performed in Franklin Research Center facilities in Philadelphia, Pennsylvania.

Consulting work or local testing may make it necessary to perform a task at other locations.

The TAF or separate--letter will identify such a requirement.

8.

Cost Ceiling l

$125,000.00 - cumulative for all' tasks.

{

4 L-

~,

O Franklin Research Center NRC Contract No. NRC-05-81-247 Task Order No. 2 Mechanical Engineering 1.

Srope of Work a.

Provide mechanical and metallurgical tests and analyses of material used in structural steel, safety related piping, mechanical components or parts thereof including proper composition, strength, fracture toughness, heat treatment and metallurgical properties.

b.

Nondestructive examinations such as ultrasonic, radiography, liquid penetrant, magnetic particle, eddy current or other methods which may be necessary for metallurgical examination.

2.

Objective of Work To provide independent technical data, records and technical assistance from laboratory test results.

To assist in investigations by analysis and evaluation of technical data submitted as a result of incidents and/or inspection support.

3.

Statement of Work Each sample or group of samples provided to Franklin Research Center for testing and/or analysis will carry a Task Authorization Form (TAF) which identifies the specific request including applicable codes and standards. The following items are examples of requests which may be submitted under this Task Order:

a.

Mechanical tests such as hardness and charpy vee notch, strength, fracture toughness values of materials and weids and other material specifications and/or metallurgical properties.

b.

Sensitization tests of stainless steel material samples and their susceptibility to intergranular attacks.'

c.

Weld metal testing for typical rods, fluxes electrodes, inserts, etc.

d.

Qualification of weld procedures.

e.

Nondestructive examinations of material samples, l

equipment or components.

O.

4.

Reporting Requirements Test results, analysis of material and/or the results of independent evaluation with the task order report shall be submitted to the TAF initiating office as indicated on the TAF.

A copy of each report shall be submitted to the Project Officer:

W. Laudan, Office of Inspection and Enforcement:

Division of Resident and Regional Reactor Inspection, U. S. Nuclear Regulatory Commission, MS-EW 359, Washington, D.C., 20555.

A monthly report combining activities under all Task Orders issued will be submit?

  • to the Contracting Officer with a copy to the Project Officer.

5.

Desired Completion Date In many instances time is of the essence and test results, analysis of material or results of independent evaluation are needed at the earliest turn around time possible, without the use of overtime or night differential.

In instances where more time is available, this will be indicated on the Test Authorization Form (TAF,'.

6.

Special Instructions or Requirements Special Instructions pertaining to the service or the follow-up report, such as proprietary information, will be made part of the TAF, or be sent by separate letter or memorandum.

Some information provioed may-be used as evidence during testimony in public hearings, and in such case will be made part of the TAF or submitted by separate letter.

7.

Place of Work l

The majority of work under this task order will be performed in Franklin Research Center facilities in Philadelphia, Pennsylvania.

Consulting work or local testing may make it necessary to perform a task at other locations.

The TAF or separate letter will identify such a requirement.

8.

Cost Ceiling

$125,000.00 - cumulative for all tasks.

O Franklin Research Center NRC Contract No. NRC-05-81-247 Task Order No. 3 Electrical and Instrumentation Engineering 1.

Scope of Work a.

Provide electrical, mechanical, pneumatic, seismic, environmental and fire testing for specific electrical and instrumentation and control components and assemblies.

2.

Objective of Work To provide independent technical data, records and technical assistance from field or laboratory test results.

To assist in investigations by analysis and evaluation of technical data submitted as a result of incidents and/or inspection support.

3.

Statement of Work Each sample or group of samples provided to Franklin Research Center for testing and/or analysis will carry a Task Authorization Form (TAF) which identifies the specific request including applicable codes and standards. The following items are examples of requests which nay be submitted under thit Task Order:

a.

Electrical equipment and component functional testing.

b.

Environmental qualification testing of typical electrical equipment and components.

c.

Electrical cable penetration firestop testing.

d.

Seismic testing of electrical, pneumatic, instru-mentation and controls components.

e.

Qualification testing of electrical cables.

4.

Reporting Requirements Test results, analysis of material and/or the results of independent evaluation with the task order report shall be submitted to the TAF initiating office as indicated on the TAF.

A copy of each report shall be submitted to the Project Officer:

W. Laudan, Office of Inspection and Enforcement:

Division of Resident and Regional Reactor.

Inspection, U. S. Nuclear Regulatory Commission, MS-EW 359, Washington, D.C., 20555.

. l A monthly report combining activities'under all Task Orders issued will be submitted to the Contracting Officer with a copy to the l

Project Officer.

5.

Desired Completion Date In many instances time is of the essence and test results, analysis of material or results of independent evaluation are needed at the earliest turn around time possible, without the use of overtime or night differential.

In instances where more time is available, this will be indicated on the Test Authorization Form (TAF).

6.

Special Instructions or Requirements Special Instructions pertaining to the service or the follow-up report, such as proprietary information, will be made part of the TAF, or be sent by separate letter or memorandum.

Some information provided may be used as evidence during testimony in public hearings, and in such case will be made part of the TAF or submitteo by separate letter.

7.

Place of Work The majority of work under this task order will be performed in Franklin Research Center facilities in Philadelphia, Peansylvania.

Consulting work or local testing may make it necessary to perform a task i

at other locations.

The TAF or separate letter will identify such a requirement.

8.

Cost Ceiling

$125,000.00 - cumulative for all tasks.

l l

l

Franklin Research Center NRC Contract No. NRC-05-81-247 Task Order No. 4 Chemical Engineering 1.

Scope of Work a.

Provide chemical analysis of material samples including quantitative analysis for inorganics and gas chromatographic spectrometric analysis.

2.

Objective of Work To provide independent technical data, records and technical assistance from field or laboratory test results.

To assist in investigations by analysis and evaluation of technical data and chemical analysis of material samples submitted as a result of incidents and/or inspection support.

3.

Statement of Work Each sample or group of samples provided to Franklin Research Cer.ter for testing and/or analysis will carry a Task Authorization Form (TAF) which identifies the specific request including applicable requirements, codes or standards.

The following items are examples of requests which may be submitted under this Task Order:

a.

Spectrographic analysis of metallic matters including molecular spectroscopy.

b.

Infrared Quantitative Analysis for identification of material.

c.

X-Ray Emission Spectrometric Analysis of Low-Alloy Steels.

4.

Reporting Requirements Test results, chemical analysis of material and results of independent evaluation with the task order report shall be submitted to the TAF initiating office as indicated on the TAF.

A copy of each report shall be submitted to the Project Officer:

W. Laudan, Office of Inspection and Enforcement:

Division of Resident and Regional Reactor Inspection, U. S. Nuclear Regulatory Commission, MS-EW 359, Washington, D.C., 20555.

A monthly report combining activities under all Task Orders issued will be submitted to the Contracting Officer with a copy to the Project Officer.

5.

Desired Completion Date In many instances time is of the essence and test results, analysis of material or results of independent evaluation are needed at the earliest i

Franklin Research Center NRC Contract No. NRC-05-El-247 Task Order No. 5 Environmental Testing 1.

Scope of Work a.

Provide environmental tests and analyses of equipment and components used in safety related systems, including independent verification and compliance with regulatory regairements and applicable codes and standards.

2.

Objective of Wurk To provide independent technical data, records and technical assistance from laboratory test results.

To assist in investigations by analysis and evaluation of technical data submitted as a result of incidents and/or inspection support.

3.

Statement of Work Each sample or group of samples provided to Franklin Research Center for testing and/or analysis will carry a Task Authorization Form (TAF) i which identifies the specific request including applicable' requirements, codes or standards.

The following items are examples of requests which may be submitted under this Task Order:

a.

Baseline test.

b.

Radiation aging.

c.

Thermal aging.

d.

Wear aging.

I e.

Vibration aging.

f.

Seismic testing.

g.

Accident radiation.

h.

Simulated LOCA/MSLB.

4.

Reporting Requirements Test results, analysis of material and/or the results of independent evaluation with the task order report shall be submitted to the TAF initiating office as indicated on the TAF.

A copy of each report shall be submitted to the Project Officer:

W. Laudan, Office of Inspection and Enforcement:

Division of Resident and Regional Reactor Inspection, U. S. Nuclear Regulatory Commission, MS-EW 359, Washington, j

D.C., 20555.

l l

. A monthly report combining activities under all Task Orders issued will be submitted to the Contracting Officer with a copy to the Project Officer.

5.

Desired Completion Date In many instances time is of the essence and test results, analysis of material or results of independent evaluation are needed at the earliest turn around time possible, without the use of overtime or night differential.

In instances where more time is available, this will be indicated on the Test Authorization Form (TAF).

6.

Special Instructinns or Requirements Special Instructions pertaining to the service or the follow-up report, such as proprietary information, will be made part of the TAF, or by separate letter or memorandum.

Some information provided may be used as evidence during testimony in public hearings, and in such case will be made part of the TAF or submitted by separate letter.

7.

Place of Work The majority of work under this task order will be performed in Franklin Research Ccr.ter facilities in Philadelphia, Pennsylvania.

Consulting work or local testing may make it necessary to perform a task at other locations.

The TAF or separata letter will iden+1fy such a requirement.

8.

Cost Ceiling

$125,000.00 - cumulative for all tasks.

Franklin Research Center NRC Contract No. NRC-05-81-247 Task Order No. 6 Fire Safety 1.

Scope of. Work a.

Provide chemical and physical tests and analysis of materials equipment F.nd systems used in the discipline of fire safety.

2.

Objective of Work To provide independent technical data, records and technical assistance from field or laboratory test results.

To assist in investigations by analysis and evaluation of fire retardent materials, fire prevention equipment and components and technical data submitted as a result of incidents and/or inspection support.

3.

Statement of Work Each sample or group of samples provided to Franklin Research Center for testing and/or analysis will carry a Task Authorization Form (TAF) which identifies the specific request including applicable codes and standards. The following items are examples of requests which may be submitted under this Task Order:

a.

Chemical and Physical Test and Analysis of Materials, Equipment and Components used in fire detection and fire prevention systems.

b.

Analysis and testing of fire retardent materials and components.

c.

Testing of fire barriers.

d.

Independent assessment of quality standards for safety related fire detection and fire prevention equipment j

and components.

4.

Reporting Requirements Test results, analysis of material, equipment, components and/or the results of independent evaluation with the task order report shall be submitted to the TAF initiating office as indicated on the TAF.

A I

copy of each report shall be submitted to the Project Officer:

W.

Laudan, Office of Inspection and Enforcement:

Division of Resident and Regional Reactor Inspection, U. S. Nuclear Regulatory Commission, MS-EW 359, Washington, D.C., 20555.

I t

t

  • . ~.

A monthly report combining activities under all Task Orders issued will be submitted to the Contracting Offi:er with a copy to the Project Officer.

5.

Desired Completion Date In many instances time is of the essence and test results, analysis of material or results of independent evaluation are needed at the earliest turn around time possible, without the use of overtime or night differential.

In instances where more time is available, this will be indicated on the Test Authorization Form (TAF).

6.

Special Instructions or Requirements Special Instructions pertaining to the service or the follow-up report, such as proprietary information, will be made part of the TAF, or by separate letter or memorandum.

Some information provided may be used as evidence during testimony in public hearings, and in such case will be made part of the TAF or submitted by separate letter.

7.

Place of Work The majority of work under this task order will be performed in Franklin Research Center facilities in Philadelphia, Pennsylvania.

Consulting work or local testing may make it necessary to perform a task at other locations.

The TAF or separate letter will identify such a requirement.

8.

Cost Ceiling

$125,000.00 - cumulative for all tasks.

_