a EASTERN MICHIGAN UNIVERSITY YPSILANTi. MICHIGAN 48197
==
JOHN W. PORTER PAESIDENT hby 22, 1981 b!r. D. J. Sreniawski, Chief Shterials Radiation Protection, Section 2 Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137
Dear >!r. Sreniawski:
Enclosed is our institutional response to the five items of noncompliance which were cited in your letter dated April 29, 1981.
This response which outlines the corrective actions that have been taken was prepared by our Acting Radiation Satety Officer, Dr. Robert Silver, I! cad of the Physics Department.
I am confident that appropriate corrective measures have been taken in response to all five violations, h'c would welcome your further in-quiry or a return site visit to verify our current compliance with NRC g
regulations.
Sing'r r,
m h'. Porter esident
/ss Enclosure f [fl,'!!;
'l l b 5
(('
j cArct 1. w m t wuv re, w;.,, cc,,,, myg, r4 coe.m h t, a, M,
- 2, uss Q7107080446 810626
'yg 2 6 581
-