_ - - _ _ _ _

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374ot 400 Chestnut Street Tower II

\\

July 1, 1981 C

?8 1.b{a T g)7 d L

Mr. Harold R. Denton, Director w

Office of Nuclear Reactor Regulation 4 0 f

U.S. Nuclear Regulatory Commission d >>-

w/

Washington, DC 20555 ig -

,% f 7,4

(

Dear Mr. Denton:

In the Matter of the

)

Docket Nos. 50-259 lj" Tennessee Valley Authority )

50-260 50-296 In response to NUREG-0737, Item II.D.1, this letter provides the results of a preliminary review of the generic BWR Safety / Relief Valve (S/RV) test program results to confirm the adequacy of the SiriV's for Browns Ferry Nuclear Plant. The S/RV test conditions are defined in the description submitted with the September 17, 1980 letter from D. B.

Waters to R. H. Vollmer. The preliminary data from the S/RV test program will be submitted on July 1, 1981, on behalf of the BWR Owners' Group in a letter from T. J. Dente to D. G. Eisenhut.

At the present time, the three-stage topworks have been replaced and Browns Ferry employs the two-stage Target Rock S/RV, Model No. 7567F.

However, we are still approved to use the three-stage topworks (Model No. 7467F) if the need arises. Based on a preliminary review of the generic BWR S/RV test program results, we believe that the tested valves satisfy the acceptance criteria for operability and that the operational adequacy of the Browns Ferry S/RV's (with both the two-and three-stage topworks) has been demonstrated.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. i. Mills, Manager Nuclear Regulation and Safety Subscribed and sworn t before me this

/

day of 1981.

G us4tAJ iothary Public U

My Commission Expires / -hb Q

4 \\\\b 1c107000377 810701 sPDR ADOCK 05000259 sj P PDR An Equal Opportunity Employer