Withdraws Request to Modify Tech Spec 3.10.A.3 Re Min Shutdown Reactivity Requirement Submitted 810428 in Proposed Change 84
ML20005B490
Person / Time
Site: Maine Yankee
Issue date: 07/02/1981
From: Groce R
Maine Yankee
To: Clark R
Office of Nuclear Reactor Regulation
References
FMY-81-99, NUDOCS 8107080290
Download: ML20005B490 (1)


Text

..

44 F

j:,j#All#EE AmmlrPawtncomFAny.

,,,,monCes1,nnoAo

{T hl ENGINEERING OFFICE FRAMINGH AM MASSACHUSETTS 017o1 617 872-8100 Ju1_y 2, 1981

%g y

FMY 81-99 2.C.2.1 g

\\

t.

United States Nuclear Regulatory Commission Washington, D.C.

20555 j

(

Attention:

Office of Nuclear Reactor Regulation 8' %

88 A Division of Licensing Ng Operating Reactors Branch #3 Mr. Robert A. Clark, Chief

.h M

  1. frT)-

References:

(a) License No. DPR-36 (Docket No. 50-309)

(b) MYAPC Letter to USNRC, FMY 81-65, Proposed Change No. 84, April 28,1981 (c) MYAPC Letter to USNRC, FMY 81-79, dated May 15, 1981

Subject:

Withdrawal of Request to Remove Shutdown Margin T.3.3.10.A.3 From Proposed Change No. 84

Dear Sir:

In Referenee (b), Maine Yankee requested the minimum shutdown reactivity requirement of Technical Specification 3.10.A.3 be deleted because that requirement is redundant to the requirement of Technical Specification 3.10.A.2.

You aisagreed on the basis that such a limit has historically been imposed. We hereby withdraw our request to modify Specification 3.10.A.3, although the issue may be discussed further at a later date.

As stated in our letter, Reference (c), the minimum available CEA worth at Hot Zero Power, at 4000 MWD /MTU burnup is 3.76% delta rho with the highest worth CEA stuck out of the core, including a 10% uncertainty. The very conservative estimate of steam line break cooldown reactivity addition is 3.57% delta rho.

As you can see our minimum available CEA worth 's core than adequate to compensate for very conservatively calculated steam line break reactivity additions. Therefore, we do not consider the availab?e shutdosm margin value of 3.2% delta rho in Technical Specification 3.10.A.3 an important issue in l

approving the cycle 6 core reload submittal. You may modify this section as deemed appropriate within the bounds of our minimum available CEA worth, although it does not seem reasonable to require more than the 3.57% delta rho reactivity addition described in Reference (c).

If you have any questions please contact us.

Very truly yours, MAINE YANKEE ATOMIC POWER COMPANY I"107080290 910702 b PDR ADOCK 05000309 Robert H. Groce UP PDR Senior Licensing Engineer

]\\

gg RHG/p1b f

1