Responds to Generic Ltr 81-01 Re Qualification of Insp,Exam & Testing & Audit Personnel.Util Has Incorporated Quality Insp & Test Functions Directly Into Station Operating Procedures
ML20005B384
Person / Time
Site: Cooper 
Issue date: 06/25/1981
From: Pilant J
NEBRASKA PUBLIC POWER DISTRICT
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
GL-81-01, GL-81-1, TAC-47099, NUDOCS 8107080159
Download: ML20005B384 (4)


Text

e GENERAL OFFICE P. o. Box 499, COLUMBUS, NEBRASKA 68601 Nebraska Public Power Distr. t ic memo ~e m se..su p >,i.A June 25, 1981

/qb b

g JL'L 0 71981 m.H Darrell G.

Eisethut, Director U5-j"g2ll,mrom Division of Licensing'

' /

Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ff Washington, DC 20555

/

Subject:

Qualification of Inspection, Examination and Testing and Audit Prrsonnel (Generic Letter 81-01)

Dear Mr. Eisenhut:

.anse to your recent directive " Qualification of Inspection, Exam-ination, and Testing and Audit PerPonnel (Generic Letter 81-01)" dated May 4, 1981, the following is presented.

Regulatory Guide 1.146 - Qualification of Quality Assurance Program Audit Personnel for Nuclear Power Plants - dated August 1980 hasponse:

.resently, Nebraska Public Power District auditor's qualification program is in compliance with the guidelines established in ANSI /ASME N45.2.23-1978 for qualifying personnel that participate in audits of quality assurance programs for nuclear power plants.

Cognizant of the continuing industry shortage of Lead Auditors, the District QA Department has established an on -going auditor's training program.

During the interim period, auditors who are not certified to ANSI /ASME N45.2.23-1978 are under the direction of qualified Lead Auditors.

In order to provide objective evidence of Lead Auditor dirt: tion to all CNS QA program auditors, the co-signature of a Lead Auditor is required on all audit reports and follow-ups per-formed by auditors.

Regulatory Guide 1.58 Revision I - Qualification of Nuclear Power Plant Inspection, Examination, and Testing Personnel

Response

NPPD's commitment to ANSI N45.2.6 " Qualification of Irapection, Examin-ation and Testing Personnel for Nuclear Power Plants" stated in section 8 of the Cooper Nuclear Station Quality Assurance Program Polic.y Document, Revision 8,is as follows:

Scope and Applicability The guidance provided by this standard and the associated Regulatory Guide 1.58 shall be applied to faspection, examination, and _esting

~8107080159 810625 0

PDR ADOCK 05000298 5d#

\\

P PDR]

Dirrell G. Eisenhut, Dirzctor June 25, 1981 Page 2 activities associated with safety related operations, including maintenance, repair, and modification except as noted below.

- Specific Exceptions It has always been the belief of CNS and NPPD that, in order to be effective, quality control must be built into the operation of the

. plant. With this in mind, CNS incorporated quality inspection and test functions directly into the station operating procedures.

Inspection points are witnessed and signed off by members of the operating staff not directly involved in the activity being inspected.

Assignment of QC inspectors is a function of station management.

The majority of the QC inspections are assigned to engineers, licensed reactor operators or lead technicians. This method for selecting and assigning inspectors has assured station management that the best qualified individual (either through education or years of experience) is assigned to monitor " essential" or safety related activities.

CNS inspectors meet the requirements listed in the following section entitled " Inspection".

Inspection First Level inspection has been assigned to plant personnel.

Con-trary to the requirement of this standard that such persons shall not report directly to the same immediate supervisor, our program requires only that inspection activities to verify quality of work shall be performed by appropriately qualified persons other than those who performed the activity being inspected. To be considered qualified, persons performing inspection or verification activitities shall meet the following requirements:

The inspector or verifier did not perform or directly supervise the work; The c"ality of work will be demonstrated by a functional test if a prest. e boundary has been breached; The verifier's qualifications are reviewed and found acceptable by the QA organization prior to initiating the verification; Individuals performing verification functions associated with normal operations of the plant will be qualified to ANSI N18.1-1971; Individuals whose qualifications are not required to meet those in ANSI N18.1-1971 and who perform verification activities shall be qualified to ANSI N45.2.6-1973 except that the QA experience cited for Levels I, II and III shall be interpreted to mean actual experience in carrying out the types of inspection, examination and testing activity being performed; and All non-destructive examinations (radiography, dye penetrant, magnetic particle, and the'like) will be performed by personnel qualified and certified in accordance with SNT-TC-1A.

4

.,--,.-y

,_-,~.y.

3 y.

-y-

,c-s-,y m-

,,.,yy.

y

Y Darr: Il G. Eir:nhut, Director June 25, 1981 Page 3 The method endorsed by ANSI N45.2.6 places emphasis on certifying individuals and establishing levels of qualification.

It is our con-tention that even though an individual is certified and qualified to the appropriate level, he may not be the best inspector in all situations.

The current method of selecting and assigning QC inspectors at CNS has proven to be very effective.

We, therefore, take exception to Sections 2.0 and 3.0 of ANSI N45.2.6.

If future operation indicates that our present system is inadequate, the Station Operating Review Committee will reevaluate the QC system and commit to ANSI N45.2.6 or provide an acceptable alternate.

CNS does not have the inhouse capability to perform non-destructive examinations in accordance with SNT-TC-1A.

These services are cur-rently contracted to an approved vendor. Any required non-destructive examinations will be performed by personnel who are qualified and certified per SNT-TC-1A.

Regulatory Positions C.5, 6, and 10

Response

As reflected in NPPD's commitment to ANSI N45.2.6, specific exception has been taken to Sections 2.0 and 3.0.

The alternative method of complying with the applicable sections of 10CFR50, Appendix B are as described in the commitment.

Regulatory Position C.7

Response

As described in NPPD's commitment, adequate steps are taken to ensure an acceptable levc' of competence in the performance of their activities.

Regulatory Position C.8

Response

Inspection activities at CNS are prescribed by work documents and procedures which are reviewed and approved by appropriate station management. These reviews include specific dedication to the aspect of radiological concerns such that it is addressed when appropriate for each circumstance.

In ad-dition to the work procedures, station administrative controls are com-mensurate with federal regulations.

CNS Health Physics Procedure 9.1.1.1 states that radiation protection training will be oriented to the activity to be performed by the individual as determined by the Health Physics Department.

Darra11 G. Eistnhut, Dirsctor

~ June 25, 1981 Page 4 Should you have any questions or comments, please contact me.

Sincerely, M9.

M. Pilant Director of Licensing and Quality Assurance JMP:FEW:cmk l