_
e Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radbactive Materials Packages 1.(al Certificate Number 1 (b) Revision No.
1.(c) Package Identifiestion No.
1.(d) Pages No. 1.(e) Total No. Peges 9149 0
USA /9149/B( )
1 2
- 2. PREAMBLE 2.tal This certifice:e is issued to satisfy Sections 173.393e.173.394,173.395, and 173.396 of the Department of Trenerortation Haaerdous Meteriais Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10e and 146-19-100 of the Department of Tr2nsportation Dangerous Cargoes Reguistions (46 CFR 146-?49), as amended.
2.lb)
The packaging and cm eats described in item 5 below, meets the safety standards set forth in Suboert C of Title 10. Code of Federal Reguistions. Part 71 ** Packaging of Radioactive Meteriais for Transport and Transportation of Radioactive Meterial Under Cartain Conditions."
d 2.lel This certificate does not relieve the consignor from comotience with any requirement of the regulations of the U.S. Department of Transportation or other applitable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.lal Prepared by (Name aid address):
3.(b)
Titte and identification of report or application:
Technical Operations, Inc.
. Technical Operations, Inc. application dated Northwest Industrial Park April 10, 1981.
Burlingten, MA 01803 71-9149 3.(c) -Docket No.
- 4. CONDITIONS This certificate is conditional upon tfie fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorised Contents, Model Number, Fissi:e Class. Other Conditir.ie, arrt References (a) Packaging
~(1) Model No.: 910 (2) Description A stainless steel encased, uranium shielded radiographic device.
l The shipping container is 13.0 inches-long, 7.7 inches high and l
S.3 inches wide. The radioactive source assembly is housed inside l
a tungsten source tube. The source tube is surrounded by l
depleted uranium metal for shielding.
The depleted uranium l
shield assembly is encased in a stainless steel housing.
The void space between the uranium shield assembly and stainless steel housing is ~ filled with a ca:,coble rigid polyuretnane foam.
j The gross weight of the container is 34.0 pounds.
l (3) Drawings The packaging is constructed in accordance with the following l
Technical Operations, Inc. Drawing Nos. 91090, Sheets 1, 2, and l
3 of 3, Rev. O and 90090, Sheets 3 and 4 of 4, Rev. O, l
I l
gjo& 24'OYN lg
Page 2 - Certificate No. 9149 - Revision No. 0 - Docket No. 71-9149 5.
(b) Contents (1) Type and fonn of Material i
Iridium-192 as sealed sources which meat the requirements I
of special-form as defined in 571.4(0) of 10 CFR Part 71.
(2) Maximum quantity of material per package 30 curies 6.-
The source must be secured in the shield position of the packaging by the source assembly. The source assembly must be fabricated of mateitals capable o' resisting a 1475'F fire environment for one--
half hour and maintaining their positioning function. The source assembly must engage the locking device. The source assembly must be of sufficient length and diameter to provide positive positic.1ing of the source within the depleted urenium shield assembly.
7.
The name plate must be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.
r 8.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CF,R 571.12(b).
~
9.
Expiration date: June 30' 1986.
~
REFERENCE Technical Operations, Inc. application dated April 10, 1981.
FJR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:
l 8
o
,e 6
-w-,
--.-e,
,,,,,-r-,.-_,--...we
.,.--,, - - -,.... - +
.~..,w.- - -., -
,.ep<-~--,-.. -..-. -,.-,,
e.e,.--.
., -, -.