Text

VIA TELECOPY i

Deholt.

acco s i-dlSOn m.cono Av %.m-June 16, 1981 g-M/

/

EF2-53,667 g j }<,,

El-

= % 4Q

%? ilk

/'f ; T Mr. L.L. Kintner Division of Project Management Office of Nuclear Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Reference:

Enrico Fermi Atomic Power Plant - Unit 2 NRC Docket No. 50-341

Subject:

GDC 51 Information Transmittal

Dear Mr. Kintner:

Detroit Edison submitted information on June ),

1981, to demon-strate that the containment pressure boundary materials were fabricated in accordance with GDC 51. We then reported the maximum wedge thickness of HPCI valve V8-2194 to be 5%".

How-ever, the vendor has subsequently indicated that, although this is the maximum thickness, 1 " is the most critical section thickness. This information is shown on the dimensional inspec-tion report previously transmitted.

Sincerely, f/

W.F. Colbert Technical Director Fermi 2 Project KH/gs godl u.

8106 22 0 @d3