ML20004F434

From kanterella
Jump to navigation Jump to search
Forwards GE Response to Question 020.27 Re Description of Effects on Safety & Operability of Control Rod Driveline Hydraulic Sys If Drive/Cooling Water Pressure Control Valve F003 Fails Either Closed or Open.Failure Not Safety Problem
ML20004F434
Person / Time
Site: Fermi 
Issue date: 06/16/1981
From: Colbert W
DETROIT EDISON CO.
To: Kintner L
Office of Nuclear Reactor Regulation
References
EF2-53699, NUDOCS 8106180340
Download: ML20004F434 (2)


Text

.

P Detr.oit ma ucm w.<

n

-. ', ' Oetmd. %c7 qv W26 313; 23MC00 n we. w w June 16, 1961 EF2 - 53699

. p \\ ~~

Y

.I h

Mr. L. L. Kintner b*gj[.1' g\\9B F Y Division of Project Management

[

  1. .;3 Office of Nuclear Reactor Regulation S% *,, g 5#

U. S. Nuclear Regulatory Comission Washington, D. C.

20555 9

Or

'.W

Dear Mr. Kintner:

Reference:

Enrico Fermi Atmic RMer Plant, Unit 2 NBC Docket No. 50-341

Subject:

Resconse to NRC Question 020.27 The subject questiori requested a description of the effects on the safety and operability'of the CRD Hydraulic System if the drive / cool-ing water pressure control valve, F003, fails either closed or open.

As the designer of the CRD Hydraulic System, General Electric prepared t'.a following response.

The function of the F003 pressure control valve (PCV) is to provide a meana of adjusting the drive water header and cooling watei-header pressures. The F003 PCV is a manually controlled notor opetated valve which is controllable from the main control room. Indicating lights are provided in the control rom for the valve full open and full closed positions. Adjustment of the F003 PCV in concert with adjustments to the F002 flow control valve pc.rmit adjustment of the drive water header pressure to approximately 260 psi above vessel pressure while, at the same time, maintaining the drive cooling water header pressure at approximately 20 psi above vessel pressure.

If the F003 PCV were to fail to a full-open position, the cooling water pressure would increase and the drive water pressure would decrease. The resulting cooling water pressure increase could cause control rods to drift inward. The existence of rod drifts would be alarmed to the control room operator for appropriate action. The g

resultingdropindrivewaterpressurewouldmakenormalcontrolrodq,[$I notch movements impossible but would not affect the ability of the V

p I

scram function.

1 8106180 W A

r-

Mr. L. L. Kintner June 16, 1981 EF2 - 53699 Page 2 Conversely, if the F003 PCV were to fail to a full-closed position, the cooling water pressure would decrease while the drive water pressure would increase. The reduction in cooling water pressure (and flow) would eventually lead to high CRD temperature being nlarmac1 in the control room. In the limiting case, the resulting increase in drive water pressure would reach up to the shutoff pressure of the supply pump (1600 psig). The occurrence of this condition dur-ing withdrawal of adrive at zero reactor pressure will result in a drive pressure increase from 260 psig to no more than 1600 psig.

al mlations indicated that the drive would accelerate from 3 inch /sec to approximately 6 inch /sec. The rod movement would stop as soon as the driving signal is removed.

In both of the cases described above, the manually operated bypass PCV (F004) in conjunction with isolation gate valves at upstream and downstream of the F003 PCV would enable the operators to take cor-rective action.

In conclusion, although the failure to the full-open or full-closed position of the drive / cooling water PCV would cause perturbation in the CRD system operation, it does not present a safety problem or affect the scram capability of the CRD system.

Sincerely,

?f?h5f W. F. Colbert Technical Director Enrico Fermi 2 WEC/MLB/dk

.