. _ _ _.
$SMUD SACRAMENTO MUNICIPAL U!iLITY DISTRICT O 6201 S Street Box 15830. Sacramento, California 95813; (916) 452 3211 June 5, 1981
\\} ! [r Q3
\\
DIRECTOR Ol' NUCLEAR REACTOR REGULATION f{
ATTENTION: DARRELL G EISENHUT, DIRECTOR 7
DIVISION OF LICENSING 31931 ".,
US NUCLEAR REGULATORY COMMISSION t; (
J
~/
> v.s.ygji$ as [/
WASHINGTON DC 20555
,f W
j ;-[/N' DOCKET N0 50.s12 RANCHO SEc0 NUCLEAR GENERATING STATION UNIT NO 1 PROPOSED AMENDMENT NO 78 In accordance with 10 CFR 50.59, the Sacramento Municipal Utility District hereby proposes to temporarily amend its Operating License, DPR-54, for Rancho Seco Nuclear Generating Station, Unit No.1 by submitting a copy of Proposed Amendment No. 78.
Appendix B, Section 2.6.2.D:
Add footnote to read; The last sentence in specification 2.6.2.D is replaced by the following paragraph during the period June 6, 1981 through June 30, 1981; "If these monitors are inoperable for a period exceeding 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, tank discharges may be continued up to 14 days provided that discharges are collected in a retention basin. The mixed retention basin will be sampled and analyzed.
Retention basin valving will be verified to prevent further addi-tions to the basin and diluted discharges from the retention basin will be sampled and analyzed every 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> during release.
Review of the above sampling technique does not increase the proba-bility of an unmonitored radiological release to the environment.
The sampling and valving will provide additional serification and confidence that 10 CFR 20 concentrations are noi. exceeded.
If you have any questions concerning this matter, please contact
- Y FiTiiTIA J CROOKS- -^g
^
Mr. R. Colombo at the Rancho Seco Nuclear Plant.
?s t
?? %.:f t'CTAF ! TCUC. CAU70RN1A G}
,r
%:'j?
- S%Cn' l' GO COtBWf G
w correaen tes.ue re. inet l
/ $
4 l
T p/ ohn.. Mattimoe
~-
Assistent General Manager Subscribed and sworn to before and Chief Engineer me this 5th day of June, 1981.
Notary Public AN tLECT'!C J y ' !! Y E ~.. N Y
~i
'4tN O
,t i
'N int HEART OF CALIF 0RNi*
810616 0 Q gf)