ML20004E769

From kanterella
Jump to navigation Jump to search
Forwards LER 81-048/03L-0.Detailed Event Analysis Encl
Date released: 01/18/2020 Download: ML20004E769


LER 81-048/03L-0:on 810514,Tech Spec Limit Containment Air Lock Leakage Rate Exceeded Design Pressure During Sp.Caused by Outer Door Seal Not Holding Pressure.Seals Repaired & Tested
ML20004E770
Person / Time
Site: Salem PSEG icon.png
Issue date: 06/08/1981
From: Espey J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20004E770 (1)
Forwards LER 81-048/03L-0.Detailed Event Analysis Encl
ML20004E768
Person / Time
Site: Salem PSEG icon.png
Issue date: 06/08/1981
From: Uderitz R
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20004E768 (2)