.....g

....._...4.

u.

.. I ATTACHIENT B SOUTHWEST RESE ARCH INSTITUTE POST OFFICE DR AwEm 286t0 522e CULEGR A ROAD SAN ANTONIO. TEM AS 79284 45123 004 511t SwRI PROJECT 02-6373 INVESTIGATION OF LP TURBINE DISC CRACKING SALEM UNIT 1 l

KEYWAY CRACK SIZE AND SHAPE 1

MARCH 26, 1981 1

i l

1 IfL

~ R *l s,~.~1o~,o.~ousrou. rex s

.~ owaso,~orou.o.c.

8106h u qg

__-_ __ ___ __ _ - __=

I 4

i SwRI Project 02-6373-002 j

Salem Unit 1, LP-3 m.7__.

x Disc No. 2, Gov. end s

f " V 'd ;; p *..,

j

,4%

b e

. /* > " k P, j

M wy s

3 g

.s w

l

~

/

e s

5 I

I x

x L

O.

t j

i k

a i'

P00RBR N' i

.,e.

l SwRI Project No. 02-6373-002 l

Salem Unit 1, LP-3 Disc No. 2, Gov, end l

i

'll s7 y-l i

l 58424 2X r

l

+ 0.42 1.51 0.215 0.28,l 1 9

0.85 y

I I

f h

d' llll

\\k'kf,//

l 0.368 h\\

/'/

0.445 s

i l

' 'M,,,/

/

i 0.62 1.01 i

I Keyway No. 1 Bolt Hole No. 1 P00RORSINA..

l

SwRI Proj ect No. 02-6373-002

?

o Salem Uni: 1, LP-3 x

Ji.

%. n.,, _. p,

+

a Disc No. 2, Gov. end 9.n.

s..,.

x i

-, ',' ' & *., 3..,, ' : h f l

?.

y,

  1. ^

e r... -N 4..-- -

l A

1 4

  • ~

j

.wi 4

s. *

~,

Y 9

s==4 R

~~

.X Wilt

?-

(

s 4.

W.i N l.3 g.

. s

. w

+

r

?

+g ai,f',.?_4. - ~,,

g..

=ig Q Q 1

, i :. h -

~

4..

H=

My - r f,

.=.

l,< b4 '

q x=

. it-I"

/

,,.. Q

(*

..

  • W, 1

t

,gg..-

l

/

..~p

, _ +

~'A g-

'..y*

ew' e gg O

Se Sm 5 %-

'*" ~:t

  • ~

-~. =

x

  • p.

M 7..

.s..w l

$l c -

.1:'

c.

'. [

.-?

+

5 e

f 9

a

  • /

r.

'4 j

3

. L

,r

'l

J 4.

)3

+-,

T y

4 '. ' p.

s. s.

y --

?

N

't's f.

.,.'*'."e.

,_ e :

..+

y 5

I f

PolR LRyg;

l SwRI Project No. 02-6373-002 Salem Unit 1, LP-3 Disc No. 2 Gov. end l

l

[

l l

58423 2X s

y 0.33 0.60 -

-f' l

l x

7 f

\\',

O.283 l

0.205

//

t

{ g I

Yf

_ 0.70 I

I i

i Keyway No. 2 Solt Hole No. 14

ATTACllMENT C IlEINSPECTION TIME FOR LP TURBINE DISCS - SALEM NUCLEAll GENEltATING STATION - 112% OVERSPEED

.P. NO.

KEYWAY NO.

DISC NO.

CRACK LENGTil CRACK GROWTl!

REINSPEC. TIME KEYWA INCllES RATE MONTliS TEMP DA/DT og IN/MO X10-2 CRITICAL MEASURED UT INDICATED ACTUAL 11 2

2 2.62

.290 2,10 22.9 299 g

12 2

2 2.89 180 2.10 28.8 299 2.06

.360

.445 2.10 13.8 299 13 1

  • 2 f>

2.06

.300

.283 2.10 17.9 299 13 2

  • 2 6

13 3

  • 2 2.06

.250 2.10 17.1 299 13 1

3 2.10

.200 1.23 32.1 238 O

13 2

3 W

2.10

.190 1.23 32.5 238 13 3

3

[

2.10

.150 1.23 34.2 238 o

NOTE:

REVISED CALCULATIONS ARE BASED ON NEW DATA RECEIVED FROM WESTINGilOUSE WITl! Ti!EIR FEBRUARY 26, 1981 LETTER AND ACTUAL CRACK SIZES FROM SOUTIIWEST BESEARCli

  • REMOVED DURING FALL, 1980 OUTAGE R. A. Demareski Revision 3 4-3-81

}.1 ATTACIMENT B SOUTHWEST RESE ARCH INSTITUTE f )S T OF FICE DR AW'.R 28610 6220 CULEBR A RO AD S AN ANTONIO. tex AS 78284 6612)664-6111 SwRI PROJECT 02-6373 IfWESTIGATION OF LP TURBINE DISC CRACKING SALEM UNIT 1 KEYWAY CRACK SIZE AND SHAPE l

l MARCH 26, 1981 l

l t

1 g-[fyl s.~.~1~,o.~oosro~

rex.s..~o..s~~oro~.o c

8" nee dk

j I

/

li P'

(

b i

3

\\

,r' j':

'i j

i 6

1 i

58396 IX 58493 8X Section 1-1 1

1 0$$

z O

$fN 3

7,

,.3 Keyway No. 1 kQ'Jl.dk <sih.*,. '.,

Bolt llole No. 1 yey u-n-

.ao WL en MN N I 58420 1X h

a w

r--

A B

SwRI Project No. 02-6373-002 Salem Unit 1, LP-3 Dise No. 2, Gov. end

{

ki$j

$.: ' ~.< -

N?f S

@fd)

TN 3

If

~'

es p: _ _ _...

58424 2.X

-4 0.42 ;

1.51 0.215 0.85 0.28

=

1 1

0.368

\\

O. 45 i

f s NNo f //

-.-.0.62 1.01 Kevvay No. 1 Bolt Hole No. 1 P00R ORENAL

r

?

~<,y-

-s O s V >,' W<'.~-

~.

~

-hhh_'_,h'i rEi. I '

i h,:-

,p,

~

. ';s4 Rl j,'

.y

=

s 4v.

' p-R ?. -

- - -.,.3'

,.:. ::M.D.:s l%,&,. 4 e.,

1

..c. -

4.

z.

y

. =,.y.

, s

..;. e
t..'t,.# -

c'.'.,

(%

.., 'g-i -9;v.;,..,

- - rn?g,,

Y :

- s

\\

w gy S

i e

. ;t;.

g 4,.

- ' ~.

t.

.. gs,. i,. - -.:. y." ) ;,;_..

.s, q 2

- re.

,f a

{

.*1.

3

., +

1p

'$6 v 4 4. ~',rp s

.r

,s.

. : : -,1'.%

3.-

L

.,y 7,..,.,%

...g t

c i

..s r e,.

__;.-g, 3

7,

c y

q-

. ; - p,..

i.,. :;.

- G 7,

~4

., 4 p7

g.. ;-

e

's A.

a' e,

i 4

3 w.

't r

r5

, w,.;gg...

. A..--,

3s, s.

4

.... t

. g,.,

g ;

3,. a

., +

e<..

a ce i n/ c.:: -

i5*

..,3

. y i

s.

q g ; ;,.,;,,

..~'

+2*g

.g;

.,3 gh '\\ 45fi&_ th.

V.

a ~

.:., _~. t

,r9 a

.am O

58395 1x 58400 4X i

i1

{

1 emm P 4 C to e o o :o W',

e D

z m

Keyway No. 2 Pyy j

T Bolt IIole No. 14 CD gQ rS l

,i

~

c3

,i "llC7 9' 2 i

sGP o d> o i

a

~

O.

8 I

w O

58421 IX Q

N I

l g

l

rs=

m 1

i-'

4

'.,(.

SwRI Project No. 02-6373-002 Salem Unit 1, LP-3 Disc No. 2, Gov. end r

,bj': ji> MI)[6t*E.

  • 58423 2X l 0.33

_ 0.60 %

e q

0.205 I.283 0

i A L

l 4,

l

.i

_ 0.70 1

l l

Keyway No. 2 Bolt Hole No. 14 I

P00RCRMA

.-.