FORM NRC-59 U.S. NUCLEAR REOUL ATORY COMMISSION (3-7 71 OFFICE OF INSPECTION AND ENFORCEMENT s
INSPECTION FINDINGS AND LICENSEE ACKNOWLEDGMENT
- s. lac E NSE E
- a. REGION AL OFFICE Departrent of the Navy U. S. Nuclear Regulatory Comission Naval Oceans System Center 1990 N. California Blvd, Suite 232 San niego California 92157 Walnut Creek California 945?G i
- 3. DOCKET NUMBER {$)
- 4. LICENSE NUMBER (5)
- 8. D ATE OF $NSPECTION 7 M q Fr/
04-im-oc
- 4. INSPECTION F8MDINGS The inspection was an esamination of the activities conducted under your license as they relate to radiation sarely and a compliance with the Commission's rules and regulations and the conditions of your license. The inspection consisted or selective esaminations. 'f procedures and repre sentative records, interviews with personnel, and observations by the inspector. The rendangs as a result of this in pattan ar s as rollows:
% No items of noncompliance or unsafe conditions were found.
The following items of noncompliance related to records, signs, and labels were found:
C A. Rooms or areas were not properly posted to indicate the presence of a RADIATION AREA.10CFR 20.203(b)or 34.42 B. R, oms or areas were not properly posted to indicate the presence of a !!!Gli RADIATION AREA.
10 CFR 20.203(c)(1) or 34.42 O
C. Rooms or areas were not properly posted to indicare the presence of an AIRBORNE RADIOACTIVITY AREA.
D. Rooms or areas were not properly posted to indicate the presence of RADIOACTIVE M ATERIAL 10 CFR 20.203(e)
O E. Containers were not properly labeled to indicate the presence of RADIOACTIVE MATERIAL.
10 CFR 20.203(f)(1) or (f)(2)
O F. A current copy of 10 CFR 20, a copy of the license,or a copy of the operating procedures was not properly posted or made available.10 CFR 20.206(b)
O G. FormNRC-3 was not properly posted.10 CFR 20.206(c)
O 11. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b)
O
- l. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d)
O J. Records of receipt, transfer, disposal, export or inventory of licensed material were not properly maintained.
10 CFR 30.51,40.61 or 70.51 i3 O
K. Records of leak tests were not maintained as prescribed in your license, or 10 CFR 34.25(cf k
O L Records ofinventories were not maintained.10 CFR 34.26 M. Utilization logs were not maintained.10 CFR 34.27 94 M N O 3'1981 s
-\\ u l
N. Records of radiation survey instrument calibration were not maintained.10 CFR 34. Q.,' kyrag 9
O O. Records of teletherapy electricalinterlock tests were not maintained as prescribed in yo I nse.
/x 0
P. Other tu AA A I
i f \\RC IrapectorY 7 The NRC Inspector has explained and I understand the items of norpompliance listed above. The items of noncompliance will be corrected within the next 30 days.
810 0 y.7 t 300 (Date)
(Licensee Representari~e - Title or Position) s ORIGINAL TO LICENSEE