ML20004D239

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 810323.Noncompliance Noted: Annual Rept for Yre Ending 800630 Not Filed
ML20004D239
Person / Time
Issue date: 04/23/1981
From: Pang J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20004D238 List:
References
NUDOCS 8106090061
Download: ML20004D239 (1)


Text

O o

APPENDIX A NOTICE OF VIOLATION C&H Electronics, Inc.

License No. 04-17260-01E 11454 Long Beach Blvd.,

Lynwood, California 90262 As a result of the inspection conducted on March 23, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7,1980), the following violation was identified:

A.

10 CFR 32.29(c) requires that an annual report must be filed with the Director of Nuclear Mater al Safety and Safeguards, U. S. Nuclear Regu-i latory Commission, Washington, D. C. 20555, with a copy to the NRC Region V office, which shall include the following information on products trans-ferred to other persons for use under 10 CFR 30.20:

(1) A description or identification of the type of each product; (2) for each radionuclide in each type of product, the total quantity of radionuclide and (3) the number of units of each type of product during the reporting period. The report shall cover the year ending June 30, and shall be filed within 30 days thereafter.

(1) Contrary to this requirement, at the time of the inspection, the annual report for the year ending June 30, 1980, had not been filed with the Director of Nuclear Material Safety and Safeguards and the Region V office.

This item constitutes a Severity Level VI violation (Supplement VII).

Pursuant to the provisions of 10 CFR 2.201, C & H Electronics, Inc., is hereby required to submit to this office within twenty-five days of the date of this Notice, a written statement or explanation in reply, including: (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further items of noncompliance; and (3) the date when full compliance will be achieved.

dated April 23,1981

  1. 40Mhwcv J. F. Pang, Radiation Specialist p,/ Radiological Safety Branch u

4 Krog

  1. '4 q.

UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

5 E

REGION V o

1990 N. CALIFORNIA BOULEVARD o

SUITE 202, WALNUT CR EEK PLAZA

+,,,a WALNUT CREEK, CALIFORNIA 94596 May 28, 1981 License No. 04-17260-ole C&H Electronics, Inc.

i 11414 Long Beach Blvd.

Lynwood, California 90262 Attention: Mr. David Frankel, Radiation Safety Officer Gentlemen:

Thank you for your letter dated May 5,1981 informing us of the steps you have taken to correct items which.we brought to your attention in our letter dated April 23, 1981. Your corrective actions will be verified during our next inspection.

Your cooperation with us is appreciated.

Sincerely, n

o L6 204

' J. E. Book, Chief Radiological Safety Branch l

l l

l 810l 0SY

4 C & H ELECTRONICS, INC.

11414 LONG BEACH BLVD.

P. O BOX 577 LYNWOOD, CALIFORNIA 90262 PHONE (213) 638-8519 OR (213) 774-3245 United States Uuclear Regulatory Comnission M1y 5, 1981 Faterials & Fuel Cycle Licensing License No; Oh-17260-01E WASHINGTON, D.C. 20$$$

Radioactive In compliance with 10 CFR 30 regarding Smoke Detector Distribution containing material. In the reporting perion from June 30 1979 to June 30 1980, no Snoke Detectors were sold containing Radioactive caterial.

This report was not filed in time, for we did not know, that even if we did not have any Sr.oke Detector sales containing Radioactive natcrial we have to file an anual report ind! iting i that no sales have been nade.

Now that we have been made aware of this requirement, we will file an anual report indicating the nunber of saics or no sales.

Sincerely Yours l

/

p I

\\

j David Frankel, Radiation Safety Officer l

/

Nf5Nf.0 '

}g gg 141981 7 4

ncioM v c/

INSPECTION &

EhfGRCEMENT,4 f

f Bi()4050'l&S l

[

APPENDIX A NOTICE OF VIOLATION C&H Electronics, Inc.

License No. 04-17260-01E 11454 Long Beach Blvd.,

Lynwood, California 90262 As a result of the inspection conducted on March 23, 1981, and in accordance with the interim Enforcement Policy, 45 FR 66754 (October 7,1980), the following violation was identified:

A.

10 CFR 32.29(c) requires that an annual report must be filed with the Director of Nuclear Material Safety and Safeguards, U. S. Nuclear Regu-latory Commission, Washington, D. C. 20555, with a copy to the NRC Region V office, which shall include the following information on products trans-ferred to other persons for use under 10 CFR 30.20:

(1) A description or identification of the type of each product; (2) for each radionuclide in each type of product, the total quantity of radionuclide and (3) the number of units of each type of product during the reporting period. The report shall cover the year ending June 30, and shall be filed within 30 days thereafter.

(1) Contrary to this requirement, at the time of the inspection, the annual r.eport for the year ending June 30, 1980, had not been filed with the Director of Nuclear Material Safety and Safeguards and the Region V office.

This item constitutes a Severity Level VI violation (Supplement VII).

Pursuant to the provisions of 10 CFR 2.201, C & H Electronics, Inc., is hereby required to submit to this office within twer.ty-five days of the date of this Notice, a written statement or explanation in reply, including: (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further items of noncompliance; and (3) the date when full compliance will be achieved.

dated April 23,1981

,ggdfMfM J. F. Pang, Radiation Specialist Radiological Safety Branch

@l0609ON

.