Text

.

O APPENDIX B NOTICE OF VIOLATION Northeast Nuclear Energy Company Docket Nos. 50-245 Millstone Nuclear Power Station 50-336 Based on the results of an NRC Health Physics Appraisal inspection conducted during August 11-22, 1980, it appears that one of your activities was not conducted in full compliance with NRC regulations and the conditions of you-license as indicated below:

10 CFR 20.201(b) " Surveys" require that such surveys be conducted as may be necessary to comply with the regulations contained in each section of Part 20.

A " Survey," as defined in paragraph 20.201(a), means "An evalua-tion of the radiation hazards incident to production, use, release, disposal, or presence of radioactive materials or other sources of radiation under a.,pecific set of conditions.

When appropriate, such evaluation includes a physical survey of the location of materials and equipment, and measure-ments of levels of radiation or concentrations of radioactive materials present." Survey requirements are further amplified in your Procedure HP 4905, " Radiological Surveys," Revision 1, and A. G. Cheatham's memo to Health Physics Personnel, dated April 10, 1979.

Contrary to the above, on August 21, 1980, three workers were allowed to install insulation in the Unit 1 Shut Down fump Room (RWP 802934) without airborne survey 3 performed prior to or during work activities to establish airborne concentrations in order to demorstrate compliance with 10 CFR 20.103.

Contamination surveys conducted in the pump room on August 19, 1980,indigatedloosesurfacecontaminationlevelsgreaterthan 500,000 dpm/100 cm beta gamma.

This is un infraction.

4f[h 8106 080

-