LER 81-042/03L-0:on 810426,while Performing Standby Gas Treatment Sys Ventilation Operability Surveillance,Refueling Floor Outlet Damper Was Found Inoperative.Caused by Faulty Pilot Solenoid Valve.Valve Was Replaced