ML20004B213

From kanterella
Jump to navigation Jump to search
Forwards LER 81-010/03L-0
Date released: 01/18/2020 Download: ML20004B213


LER 81-010/03L-0:on 810420,leaking Relief Valve Was Found on Letdown Sys.Caused by Cracked Bellows Due to Increasing Differential Pressure as Result of Crud Buildup.Valve Repaired & Reinstalled
ML20004B217
Person / Time
Site: Ginna Constellation icon.png
Issue date: 05/19/1981
From: Spector S
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20004B217 (1)
Forwards LER 81-010/03L-0
ML20004B212
Person / Time
Site: Ginna Constellation icon.png
Issue date: 05/19/1981
From: Maier J
ROCHESTER GAS & ELECTRIC CORP.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20004B212 (1)