<,o P E LT O N CAS TE E L. IN C.
9 PELTON CASTEEL, INC.
TABLE OF ORGANIZATION President C.E.O.
Vice President Mfg.
Manager Technical Manager Manager Services Mfg.
Eng.
I l Laboratories l l Foundry Eng.l l Quality Assurance l Ica=a tad l Manager of Technical Services is Administrative and Safety Officer as approved in NCR Lic. 48-02669-02.
\\
18916 81051100g7
PELTON CASTEEL QUALITY ASSURANCE, PERTAINING TO TRANSPORTATION PACKAGING FOR TRANSPORTATION OF 3Y-PRODUCT MATERIAL A.
Purpose of Quality Assurance Program:
1.
Pelton Casteel, Inc. establishes this Quality Assurance Program to assure that all requirements for control procedures and package design, as required by 10CFR71 and approved by the Nuclear Regulatory Commission, shall be implemented.
2.
The program shall assure that specific control procedures will be formulated and followed whenever a shipping package containing by-product material is received by, or is shipped from Pelton Casteel, Inc.
3.
Quality Assurance Program:
~
1.
All by-product material received by, or sent out from Pelton Casteel, Inc. shall be shipped in an N. R. C. approved shipping package.
2.
Only shipping packages owned and supplied by certified suppliers shall be used for transportation of by-product material by Pelton Casteel, Inc. Radiographic facility.
3.
All shipments transferred as in (1) above shall be tagged, identi-fled and marked in accordance with 10CFR71 requirements.
t 4
Prior to receipt, or shipment by Pelton Casteel. Inc., of a shipping package supplied by a certified supplier, a certification from the supplier will be furnisned to Pelton Casteel, Inc. stating that all regulations pertaining to design, and engineering, identification, labeling, and all other items required have been approved by the N. R. C. and that said package is capable of transporting the sper.ified by-product material safely and in accordance with N. R. C.
criteria. The supplier certification and copies of all shipping instructions shall be filed at the Pelton Casteel, Inc. Radiographic Facility and shall be readily retrievable.
5.
Transfer at Pelton Casteel, Inc. of by-product material into or out of the shipping package shall be done by a certified radiographer in accordance with suppliers recommended procedure, and instructions as stated in the operating manual of the Pelton Casteel, Inc.
By-Product License.
6.
Shipping precautions and procedures:
Incoming or outgoing shipments containing product material a.
shall be monitored with a calibrated survey meter to ascertain that radiation level is acceptable. The survey results shall be entered in the log book of the Radiographic Facility.
F----
Paga Two P E LT O N CAS TE E L,IN C.
b.
Visual inspection shall be made to package to ascertain if any physical damage of package is evident. Results of findings shall be recorded in log book of Radiographic Facility.
c.
Visual inspection shall be made to package to ascertain that all labels, markings and identification are present as' required by N. R. C. regulation. Entry of findings shall be entered in log book of Radiographic Facility.
d.
All records required shall be readily retrievable.
e.
Any shipping container arriving at the Pelton Casteel, Inc.
facility which shall be found not to meet.all N. R. C.
criteria for shipping packages shall be placed undisturbed in safe storage in the Radiographic Facility and the L R. C.
immediately notified. The package will remain undisturbed
~
until specific instructions are received from the N. L C.
as to proper action to be taken. The facility Radiographer will maintain security of package until N. R. C. instructions are forthcoming.
f.
No transfer of by-product material to or from a shipping package, or receipt, or shipment of a shipping package shall be made to or from the Pelton Radiographic Facility except under the direct supervision of a qualified Radiographer and with full knowledge of the Radiation Safety Officer and the Administrator, g.
All transfers of by-product material shall be in accordance with step by step standard procedures as stated in the Pelton Casteel, Inc. Radiographic operating manual which is part of the Pelton Casteel, Inc. By-Product License.
C.
Organization:
1.
The Radiation Safety Officer as established in the Pelton Casteel,
{
Inc. By-Product License shall be directly responsible to see that l
all requirements of the Program are met.
' He shall be notified whenever a shipping package is a.
received by, or sent out from Pelton Casteel, Inc.
i b.
He shall ascertain that said shipments are in compliwa with requirements of 10CFR71 and the Pelton Quality l
Assurance Program for Transportation Packaging.
l c.
He shall enter statement in the Pelton Radiographic Facility log book that compliance has been met.
2.
The Radiographer as established in the Pelton Casteel, Inc.
By-Product License shall ascertain that all by-product shipments into or from, the Pelton Casteel, Inc. Radiographic Facility meet all requirements of 10CFR71 and the Pelton Radiographic operations manual.
(Part of Pelton By-Product License. )
~
Paga Thrso P E LT O N - CAS TE E L. I N C.
He shall enter his findings in the Pelton Padiographic a.
Facility log book.
b.
No change may be made in this program without approval of the Padiation Safety Officer and Administrator, and unless final approval is made by the Nuclear Regulatory Commission.
~
3.
h*e will not build or possess shipping containers or packages of Pelton design or manufacture but will transport licensed amounts of by-product material for disposal or replacement in containers or packages owned and licensed by approved suppliers of by-product uncerials.
9 ee t
.ee-m s
f e
e e*
e J
1 I
18916
. -