| | | Reporting criterion |
|---|
| 05000366/LER-1981-001-03, /03L-0:on 810102,during Refueling,Drywell Isolation Valve 2T48/F209 Found Leaking When LLRT Performed on Drywell to Torus Dp Sys.Caused by Scratches on Valve Seat Due to Valve Closing on Debris | /03L-0:on 810102,during Refueling,Drywell Isolation Valve 2T48/F209 Found Leaking When LLRT Performed on Drywell to Torus Dp Sys.Caused by Scratches on Valve Seat Due to Valve Closing on Debris | |
| 05000366/LER-1981-001, Forwards LER 81-001/03L-0.Detailed Event Analysis Encl | Forwards LER 81-001/03L-0.Detailed Event Analysis Encl | |
| 05000321/LER-1981-001, Forwards LER 81-001/01T-0 | Forwards LER 81-001/01T-0 | |
| 05000321/LER-1981-001-01, /01T-0:on 801228,HPCI Steam Line Pressure Switches 1E41-N001a,c,d Actuated Outside Tech Specs.Caused by Switch Setpoint Drift.Switches Recalibr | /01T-0:on 801228,HPCI Steam Line Pressure Switches 1E41-N001a,c,d Actuated Outside Tech Specs.Caused by Switch Setpoint Drift.Switches Recalibr | |
| 05000366/LER-1981-002, Forwards LER 81-002/03L-0 | Forwards LER 81-002/03L-0 | |
| 05000366/LER-1981-002-03, /03L-0:on 810106,reactor Core Isolation Cooling Steamline Pressure Switches 2E51-NO19A & C Were Found to Actuate Below Tech Spec Limits.Caused by Setpoint Drift. Switches Recalibr | /03L-0:on 810106,reactor Core Isolation Cooling Steamline Pressure Switches 2E51-NO19A & C Were Found to Actuate Below Tech Spec Limits.Caused by Setpoint Drift. Switches Recalibr | |
| 05000321/LER-1981-002, Forwards LER 81-002/03L-0 | Forwards LER 81-002/03L-0 | |
| 05000321/LER-1981-002-03, /03L-0:on 810101,more than 5 Gpm Leaked Into Drywell W/Reactor at 401 Mwe.Caused by Mechanical Seal Leaking Water from Reactor Recirculation pump,1B31-C001A. Seal Replaced | /03L-0:on 810101,more than 5 Gpm Leaked Into Drywell W/Reactor at 401 Mwe.Caused by Mechanical Seal Leaking Water from Reactor Recirculation pump,1B31-C001A. Seal Replaced | |
| 05000366/LER-1981-003-03, /03L-0:on 810223,core Max Fraction of Limiting Power Density Found to Be Greater than Frtp During Startup. Caused by Time Delays for Adjusting Rods,Running Transient Incore Probe Scans & Processing Time for Computer | /03L-0:on 810223,core Max Fraction of Limiting Power Density Found to Be Greater than Frtp During Startup. Caused by Time Delays for Adjusting Rods,Running Transient Incore Probe Scans & Processing Time for Computer | |
| 05000321/LER-1981-003-03, /03L-0:on 810130,HPCI Governor Valve Stuck Open. Caused by Lift Rod Being Bent & Galled Due to Interference Between Lift Rod Fork Connector & Valve Lever.Damaged Rod Replaced,Upper Guide Bushing Honed & Fork Modified | /03L-0:on 810130,HPCI Governor Valve Stuck Open. Caused by Lift Rod Being Bent & Galled Due to Interference Between Lift Rod Fork Connector & Valve Lever.Damaged Rod Replaced,Upper Guide Bushing Honed & Fork Modified | |
| 05000366/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | |
| 05000321/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | |
| 05000366/LER-1981-004, Forwards LER 81-004/03L-0 | Forwards LER 81-004/03L-0 | |
| 05000366/LER-1981-004-03, /03L-0:on 810122,nozzle Loads Found Exceeding Vendor Allowables for Reactor Core Isolation Cooling Steam Turbine During Reanalysis of Piping & Hangers Per IE Bulletin 79-14.Caused by Ae Error in Sys Design | /03L-0:on 810122,nozzle Loads Found Exceeding Vendor Allowables for Reactor Core Isolation Cooling Steam Turbine During Reanalysis of Piping & Hangers Per IE Bulletin 79-14.Caused by Ae Error in Sys Design | |
| 05000321/LER-1981-004, Forwards LER 81-004/03L-0 | Forwards LER 81-004/03L-0 | |
| 05000321/LER-1981-004-03, /03L-0:on 810106,w/unit in Steady State Power Operation,Qa Audit Showed That Temporary Procedure Change HNP-818 Was Not Approved by Plant Manager within 14 Days of Implementation.Caused by Deletion of Requirement | /03L-0:on 810106,w/unit in Steady State Power Operation,Qa Audit Showed That Temporary Procedure Change HNP-818 Was Not Approved by Plant Manager within 14 Days of Implementation.Caused by Deletion of Requirement | |
| 05000366/LER-1981-005-01, /01T-0:on 810126,reactor Pressure Vessel Core Spray Loops Discovered Inoperable.Caused by Procedure HNP-2-1230 Being Performed,Closing Manual Injection Valves 2E21-F007A & B.Valves Reopened & Procedure Changed | /01T-0:on 810126,reactor Pressure Vessel Core Spray Loops Discovered Inoperable.Caused by Procedure HNP-2-1230 Being Performed,Closing Manual Injection Valves 2E21-F007A & B.Valves Reopened & Procedure Changed | |
| 05000366/LER-1981-005, Forwards LER 81-005/01T-0 | Forwards LER 81-005/01T-0 | |
| 05000321/LER-1981-005-03, /03L-0:on 810113,during Steady State Operation, Drywell Temp Recorder IT47-R612 Found to Be Inoperative. Caused by Misalignment of Cam Follower Contact W/Main Programming Cam.Follower Adjusted to Maintain Contact W/Cam | /03L-0:on 810113,during Steady State Operation, Drywell Temp Recorder IT47-R612 Found to Be Inoperative. Caused by Misalignment of Cam Follower Contact W/Main Programming Cam.Follower Adjusted to Maintain Contact W/Cam | |
| 05000321/LER-1981-005, Forwards LER 81-005/03L-0 | Forwards LER 81-005/03L-0 | |
| 05000366/LER-1981-006, Forwards LER 81-006/03L-0 | Forwards LER 81-006/03L-0 | |
| 05000366/LER-1981-006-03, /03L-0:on 810123,standby Gas Treatment Sys Filter train,2T46-D001A,removed Less Halogenated Hydrocarbon Refrigerant Gas than Required by Tech Specs During Testing by Vendor.Caused by Defective Charcoal in Filter Bed | /03L-0:on 810123,standby Gas Treatment Sys Filter train,2T46-D001A,removed Less Halogenated Hydrocarbon Refrigerant Gas than Required by Tech Specs During Testing by Vendor.Caused by Defective Charcoal in Filter Bed | |
| 05000321/LER-1981-006, Forwards LER 81-006/03L-0 | Forwards LER 81-006/03L-0 | |
| 05000321/LER-1981-006-03, /03L-0:on 810119,standby Liquid Control Pump a Discharge Relief Valve 1C41-F029A Operated Outside Tech Spec.Caused by Setpoint Drift.Valve Reset | /03L-0:on 810119,standby Liquid Control Pump a Discharge Relief Valve 1C41-F029A Operated Outside Tech Spec.Caused by Setpoint Drift.Valve Reset | |
| 05000321/LER-1981-007, Forwards LER 81-007/03L-0 | Forwards LER 81-007/03L-0 | |
| 05000321/LER-1981-007-03, /03L-0:on 810203 & 19,unit 1 Cable Spread Room Sprinkler Sys Was Inoperable for Period Greater than 14 Days & Special Repts Were Not Issued.Caused by Personnel Error. Personnel Reinstructed | /03L-0:on 810203 & 19,unit 1 Cable Spread Room Sprinkler Sys Was Inoperable for Period Greater than 14 Days & Special Repts Were Not Issued.Caused by Personnel Error. Personnel Reinstructed | |
| 05000366/LER-1981-007-03, /03L-0:on 810126,discovered That on 810124 & 25 Reactor Coolant Sampled from Wrong Sample Line.Caused by Lack of Communication Among Personnel Who Collect & Analyze Reactor Coolant.Personnel Instructed & Coolant Sampled | /03L-0:on 810126,discovered That on 810124 & 25 Reactor Coolant Sampled from Wrong Sample Line.Caused by Lack of Communication Among Personnel Who Collect & Analyze Reactor Coolant.Personnel Instructed & Coolant Sampled | |
| 05000366/LER-1981-007, Forwards LER 81-007/03L-0 | Forwards LER 81-007/03L-0 | |
| 05000321/LER-1981-008-03, /03L-0:on 810216,in Normal Operations at 309 Mwt, 1E51-N012A,B,C & D Actuated at 10.2,11.3,11.2 & 10.7 Psig, Respectively.Caused by Switch Setpoint Drift.Barksdale Switches Recalibr | /03L-0:on 810216,in Normal Operations at 309 Mwt, 1E51-N012A,B,C & D Actuated at 10.2,11.3,11.2 & 10.7 Psig, Respectively.Caused by Switch Setpoint Drift.Barksdale Switches Recalibr | |
| 05000321/LER-1981-008, Forwards LER 81-008/03L-0 | Forwards LER 81-008/03L-0 | |
| 05000366/LER-1981-008, Forwards LER 81-008/03L-0 | Forwards LER 81-008/03L-0 | |
| 05000366/LER-1981-008-03, /03L-0:on 810119,pressure Switches Were Found Out of Tolerance.Caused by Setpoint Drift.Pressure Switches Recalibr & Returned to Svc | /03L-0:on 810119,pressure Switches Were Found Out of Tolerance.Caused by Setpoint Drift.Pressure Switches Recalibr & Returned to Svc | |
| 05000366/LER-1981-009-03, /03L-0:on 810212,reactor Coolant Not Analyzed Once Per 24-h as Required by Tech Spec.Caused by Reactor Vessel Hydro During Time Period When Next Conductivity Measurement Was to Be Taken | /03L-0:on 810212,reactor Coolant Not Analyzed Once Per 24-h as Required by Tech Spec.Caused by Reactor Vessel Hydro During Time Period When Next Conductivity Measurement Was to Be Taken | |
| 05000366/LER-1981-009, Forwards LER 81-009/03L-0 | Forwards LER 81-009/03L-0 | |
| 05000321/LER-1981-009-03, /03L-0:on 810206,nitrogen Storage Tank Inventory Went Below 2000 Gallon Tech Spec Requirement.Caused by Supplier Delaying Shipment.Shipment Received.Supplier Instructed Not to Delay Shipments | /03L-0:on 810206,nitrogen Storage Tank Inventory Went Below 2000 Gallon Tech Spec Requirement.Caused by Supplier Delaying Shipment.Shipment Received.Supplier Instructed Not to Delay Shipments | |
| 05000321/LER-1981-009, Forwards LER 81-009/03L-0 | Forwards LER 81-009/03L-0 | |
| 05000366/LER-1981-010, Forwards LER 81-010/03L-0 | Forwards LER 81-010/03L-0 | |
| 05000366/LER-1981-010-03, /03L-0:on 810222,reactor Core Isolation Cooling Auto Flow Controller Did Not Control Turbine Properly While in Auto Position During Quickstart Test.Caused by Loose Ribbon Connector on Flow Control M-4 Station | /03L-0:on 810222,reactor Core Isolation Cooling Auto Flow Controller Did Not Control Turbine Properly While in Auto Position During Quickstart Test.Caused by Loose Ribbon Connector on Flow Control M-4 Station | |
| 05000321/LER-1981-010, Forwards LER 81-010/01T-0 | Forwards LER 81-010/01T-0 | |
| 05000321/LER-1981-010-01, /01T-0:on 810211,AE Reported That Diesel Generator 1A,1C,2A,2B & 1B Outlet Svc Water Piping & Associated Seismic Supports Exceeded Tech Spec.Caused by Design Omission.Design Mods Made | /01T-0:on 810211,AE Reported That Diesel Generator 1A,1C,2A,2B & 1B Outlet Svc Water Piping & Associated Seismic Supports Exceeded Tech Spec.Caused by Design Omission.Design Mods Made | |
| 05000321/LER-1981-011-03, /03L-0:on 810214,liquid Radwaste Sample Tank, WSTB1,discharged Prior to Analysis,Contrary to Ets.Caused by Technician Error in Collecting Unit 2 Radwaste Sample in Prelabeled Unit 1 WSTB-1 Bottle | /03L-0:on 810214,liquid Radwaste Sample Tank, WSTB1,discharged Prior to Analysis,Contrary to Ets.Caused by Technician Error in Collecting Unit 2 Radwaste Sample in Prelabeled Unit 1 WSTB-1 Bottle | |
| 05000321/LER-1981-011, Forwards LER 81-011/03L-0 | Forwards LER 81-011/03L-0 | |
| 05000366/LER-1981-011-03, /03L-0:on 810204,nonrated Window Discovered in 3-h Rated Fire Wall.Caused by Design,Mfg & Const/Installation Error.Direct Conversion Reactor Study 81-48 Submitted & Fire Watch Established | /03L-0:on 810204,nonrated Window Discovered in 3-h Rated Fire Wall.Caused by Design,Mfg & Const/Installation Error.Direct Conversion Reactor Study 81-48 Submitted & Fire Watch Established | |
| 05000366/LER-1981-011, Forwards LER 81-011/03L-0 | Forwards LER 81-011/03L-0 | |
| 05000321/LER-1981-012-03, /03L-0:on 810228,turbine Failed to Trip on Overspeed.Caused by Dried Lubrication Around Overspeed Tripping Mechanisms Causing Binding.Mechanism Disassembled, Cleaned,Relubricated & Reassembled | /03L-0:on 810228,turbine Failed to Trip on Overspeed.Caused by Dried Lubrication Around Overspeed Tripping Mechanisms Causing Binding.Mechanism Disassembled, Cleaned,Relubricated & Reassembled | |
| 05000321/LER-1981-012, Forwards LER 81-012/03L-0 | Forwards LER 81-012/03L-0 | |
| 05000366/LER-1981-012-02, /02L-0:on 810224,during Surveillance Testing, Standby Liquid Control Pump B Failed to Start,Losing Squibb Valve B Continuity.Caused by Failure of Control Fuse in Circuit Breaker.Fuse Replaced | /02L-0:on 810224,during Surveillance Testing, Standby Liquid Control Pump B Failed to Start,Losing Squibb Valve B Continuity.Caused by Failure of Control Fuse in Circuit Breaker.Fuse Replaced | |
| 05000366/LER-1981-012, Forwards LER 81-012/02L-0 | Forwards LER 81-012/02L-0 | |
| 05000366/LER-1981-013, Forwards LER 81-013/03L-0 | Forwards LER 81-013/03L-0 | |
| 05000321/LER-1981-013-03, /03L-0:on 810228,HPCI Sys Was Declared Inoperable When Oil Line Near Rear Bearing Broke.Caused by Person Stepping on Oil Line & Turbine Vibration Finishing Separation.Line Repaired | /03L-0:on 810228,HPCI Sys Was Declared Inoperable When Oil Line Near Rear Bearing Broke.Caused by Person Stepping on Oil Line & Turbine Vibration Finishing Separation.Line Repaired | |