Other: A01413, Requests Addl Time to Prepare License Amend Application Requested 801121 Re Tech Spec Revisions for Snubber Surveillance.Replacement Program Will Require Shutdown Scheduled by 810501.Tech Specs to Be Proposed by 810701, A01531, Responds to IE Bulletin 81-01, Surveillance of Mechanical Snubbers. All Piping Sys W/Inoperable Mechanical Snubbers Supplied by Intl Nuclear Safeguards Corp Are Acceptable for Continued Operation.Inoperable Snubbers Were Replaced, ML20003E149, ML20003E183, ML20003G079, ML20003H649, ML20009C918, ML20064J283, ML20080J661, ML20080K241, ML20094Q362
|
MONTHYEARML20064J2831979-01-0808 January 1979 Forwards Proposed Revisions to Tech Specs to Amend Operating License Project stage: Other ML20003E1491981-02-19019 February 1981 Responds to IE Bulletin 81-01, Mechanical Snubbers. Outlines Approach Being Pursued to Fully Respond to Request. Visual & Manual Insp Program Planned.Operability Testing to Be Performed on Stored Snubbers.Drawing Encl Project stage: Other ML20003E1831981-02-24024 February 1981 Responds Further to IE Bulletin 81-01, Mechanical Snubbers. Visual & Manual Insp Program Commenced.Course of Action Outlined in Will Be Pursued Project stage: Other ML20003G0791981-03-11011 March 1981 Updates Response to IE Bulletin 81-01, Surveillance of Mechanical Snubbers. Util Will Visually Examine & Stroke Test All Accessible Snubbers by 810320 Project stage: Other A01413, Requests Addl Time to Prepare License Amend Application Requested 801121 Re Tech Spec Revisions for Snubber Surveillance.Replacement Program Will Require Shutdown Scheduled by 810501.Tech Specs to Be Proposed by 8107011981-03-13013 March 1981 Requests Addl Time to Prepare License Amend Application Requested 801121 Re Tech Spec Revisions for Snubber Surveillance.Replacement Program Will Require Shutdown Scheduled by 810501.Tech Specs to Be Proposed by 810701 Project stage: Other ML20003H6491981-04-16016 April 1981 Responds to IE Bulletin 81-01, Surveillance of Mechanical Snubbers. Snubbers in Containment Will Be Replaced Prior to Startup from Next Refueling Outage Project stage: Other ML20004B6151981-04-27027 April 1981 Submits Supplemental Response to IE Bulletin 81-01, Surveillance of Mechanical Snubbers. Manual Stroke Tests Sent on 810327.Identification of Snubbers Installed on LPIS Submitted on 810416.Snubber to Be Replaced by 810501 Project stage: Supplement A01531, Responds to IE Bulletin 81-01, Surveillance of Mechanical Snubbers. All Piping Sys W/Inoperable Mechanical Snubbers Supplied by Intl Nuclear Safeguards Corp Are Acceptable for Continued Operation.Inoperable Snubbers Were Replaced1981-05-18018 May 1981 Responds to IE Bulletin 81-01, Surveillance of Mechanical Snubbers. All Piping Sys W/Inoperable Mechanical Snubbers Supplied by Intl Nuclear Safeguards Corp Are Acceptable for Continued Operation.Inoperable Snubbers Were Replaced Project stage: Other ML20009C9181981-07-16016 July 1981 Proposed Tech Specs 3/4.7.8 Re Inservice Surveillance of Snubbers & Tables 3.7-1a & 3.7-1b Project stage: Other ML20094Q3621983-08-18018 August 1983 Technical Evaluation Rept on Proposed Tech Spec Changes for Inservice Surveillance of Safety-Related Hydraulic & Mechanical Snubbers at Millstone Nuclear Power Station, Unit 2 Project stage: Other ML20080J6611983-08-18018 August 1983 Proposed Tech Spec Changes for Inservice Surveillance of Safety-Related Hydraulic & Mechanical Snubbers at Millstone Nuclear Power Station,Unit 2, Technical Evaluation Rept Project stage: Other A03502, Application for Amend to License DPR-65,revising Tech Specs Re Inservice Insp of Hydraulic & Mechanical Snubbers1984-01-18018 January 1984 Application for Amend to License DPR-65,revising Tech Specs Re Inservice Insp of Hydraulic & Mechanical Snubbers Project stage: Request ML20080K2411984-01-31031 January 1984 Proposed Tech Specs Re Snubber Surveillance Requirements Project stage: Other ML20094Q3521984-08-0202 August 1984 Amend 96 to License DPR-65,clarifying Frequency for Visual Insps,Providing Requirements for Functional Testing of Snubbers,Revising Method of Snubber Listing to Incorporate Addl Info & Clarifying Testing Acceptance Criteria Project stage: Approval 1981-04-27
[Table View] |
Text
fre IW It'11I19UIT trril,rrIIES
]
O Z.l'J.!"l?"i*f'"
$8 o$ connecticut osiot
- .*;..,:::l.';' ::"*"
a m m set 1 L
t. ;
- r1
- ,:s', :::,":. " :::
February 24, 1981 Age g
p\\
g f Docket Cos. 50-213 k(([p i[ h h 6
50-245 j
50-336 A015311C3- 0 2C 7
1981u 9 Mr. Boyce H. Grier, Director
(\\ %,IdE%ce, [
f(
[. v@.
Region I Office of Inspection and Enforcement U. S. Nuclear Regulatory Cc==ission mi' 631 Park Avenue King of Prussia, PA 19406
Reference:
(1)
W. G. Counsil letter to 3. H. Grier, dated February 19, 1981.
Gentlemen:
Haddam Neck Plant Millstone Nuclear Po.ar Station, Unit Nos.1 and 2 I&E Eulletin No. 81-01, Mechanical Snubbers In Reference (1), the NRC Staff was provided with the details of the approach which the Connecticut Yankee Atomic Power Company (CYAFCO) and Northeast nuclear Energy Company (UNECO) are implementing to fully and ec=pletely re-spond to the concerns identified in I&E Bulletin No. 81-01.
In order to meet the commitments delineated in Reference (1), ICIECO is cc==encing to perform the visual and =anual inspections at Millstone Unit No. 2, as described in Reference (1), today.
In the absence of a negative response to the Reference (1) submittal, it is the intention of CYAPC0 and :CIECO to pursue the course of action outlined in Reference (1). Notification to the contrary will result in a need for a revision to the plans and schedule outlined in Reference (1).
Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY NORTHEAST NUCLEAR E'IERGY COMPANY Y
,ip [.
. %(/;1dv W. G. Counsil Senior Vice President 8184 0e o417