Text

' W.

NUCLE AR ENE AGv BUS: NESS GROUP

  • GENE R AL E LECTRIC COM7 ANv SAN JOSE, C ALIFORN6 A 9$12$

G E N E R A L h. E LE CT R I C APPLICABLE TO:

NEDO-24082 ERRATA And ADDENDA 77NED356 T, E No -

5HEET LOCA ANALYSIS FOR PEACH 7,T gE BOTTOM ATOMIC POWER STATION March 1981 DATE UNIT 3 NO TE Correct o!Icooirs of the sophcable OOOODEOE 507I mblicattors as wds& Mow sSSJE D ATE REFERENCES INST R U CTIONS

,jS,E,C 7 ' O,* j ^jy g,

E ITE Y geonatcTeoN5 AND ACD'T'ONSI 3

l t

1 Page 4-14 Replace with new page 4-14.

l l

l t

I i

l l

I e

I 1 of 1

' AGE l

8104020S N

NE00-24082 Table 4-3h l

MAFLHGR VERSUS AVERAGE PLANAR E:GOSURE Fuel Type: P8DRB299 Flant:

p g _3_

Average Planar Ex?osure

3.\\? LHGR

?CT 0xidation r tud / t )

(kh'/ f t)

('F)

Fraction e

l 200 10.9 1768 0.006 1.000 11.0 1772 0.006 3,000 11.5 1817 0.007 10,000 12.2 1894 0.009 15,000 12.3 1923 0.010 20,000 12.1 1906 0.010 25,000 11.6 1856 0.008 30,000 10.9 1776 0.006 35,000 10.3 1703 0.004 40,000 9.6 1629 0.003 4-14