Interim Rept Re Potential Significant Deficiency or Potential Substantial Safety Hazard Re Circuit Board Failure in Westinghouse 7300 Nuclear Power Plant Control Instrumentation,Initially Reported on 810219
ML20003D534
Person / Time
Site: Summer 
Issue date: 03/20/1981
From: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8103270620
Download: ML20003D534 (1)


Text

f south CAROLINA ELECTRIC a gas CcHPANY mss our.cn.onses m

CotuuseA. Souin Canotina aseis

{

-I j)

/ / g[

f I IO

/

7. C. Nicwots.v -

9 March 20, 1981 wu mo... o. c.

w-gjg we. c O

'M R 2 6L981 $

" MW^"* b Mr. James P. O'Reilly, Director 9

p

/

U. S. Nuclear Regulatory Coc=ission Cu Region II, Suite 3100 g gs/

101 Marietta Street, N. W.

Atlanta, Georgia 30303

Subject:

Virgil C. Summer Nuclear Station Docket No. 50/395 Potential Substantial Safety Hazard or Potential Significant Deficiency Interim Repert Nuclear Eng. File 3.1051

Dear Mr. O'Reilly:

On Thursday, February 19, 1981, Mr. Virgil Brownlee of NRC Region II was notified of a potential significant deficiency or potential substantial safety hazard concerning circuit board failure in Westinghouse 7300 series Nuclear Power Plant Control Instrumentation.

Nuclear Engineering is presently reviewin ~:he number of failures that have occurred since the control instrumentation has oeen installed. Since the scope of the review is broad, the final report is not expected until two or three months.

Very truly yours, T. C. Nichols, Jr.

TB:TCN:gib cc:

V. C. Summer J. B. Knotts, Jr.

G. H. Fischer J. L. Skolds T. C. Nichols, Jr.

B. A. Bursey O. W. Dixon, Jr.

O. S. Bradham C. A. Price Document Management Branch D. A. Naur.an (55e/21/LER only)

W. A. Williams, Jr.

I&E (Was'aington) g/7 R. B. Clary ISEG I

A. R. Koon PRS A. A. Smith NPCF H. N. Cyrus File f

~9103270620