ML20003C284

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Apparent Insulation Failure of Rockbestos Firewall III Control Cable,Initially Reported 810127.Tests Indicate That Conductor Had Exploded Through Insulation, Causing Short.Matl Not Dependable After LOCA
ML20003C284
Person / Time
Issue date: 01/30/1981
From: Blythe R
ROTORK CONTROLS, INC.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-81-359-000 PT21-81-359, PT21-81-359-000, NUDOCS 8102270563