ML20003C098

From kanterella
Jump to navigation Jump to search
Forwards LER 81-014/03L-0
Date released: 01/17/2020 Download: ML20003C098


LER 81-014/03L-0:on 810129,instrument Functional Surveillance Test of LPCI Cross Connect Valve Alarm Not Performed Per Tech Specs.Caused by Lack of Surveillance Test Procedure Due to Personnel Error.Test F-ST-2T Written
ML20003C102
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/23/1981
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20003C102 (1)
Forwards LER 81-014/03L-0
ML20003C097
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/23/1981
From: Pasternak R
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20003C097 (1)