Certificate of Compliance 9079,Revision 6 for Model HN-100, Series 2A
ML20003B433
Person / Time
Site: 07109079
Issue date: 02/02/1981
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20003B431 List:
References
NUDOCS 8102100799
Download: ML20003B433 (3)


Text

--___

O Form NRC418 U.S. NUCLEAR REGULATORY CoMMIS$10N n2 731 CERTIFICATE OF COMPUANcE

,, gp q 7, For Radioactive Meterials Peckages 1.(al Certi icate Nuneer 1.lb) Revinson Nu.

1.(c) Package scentification No.

1.fdl Pages No. 1.(el Total No. Pesos f

9079 6

USA /9079/A 1

3

~

2. PREAMBLE 2.tal This cartes.cete is ensued to estisfy Sections 173.393e.173.394,173.395, and 173.396 of the ossertment of Tronoportation Hesertsous Meterials Regulatens 149 CFR 170100 and to CFR 103) and Sectens 146-19-10e and 146-19-10o of the oasertment of Transporteten oenesrous Cargoes Reewiations (46 CFR 146-149), as amended.-

2.tbl The pochee.no and contents descreed in hem 5 below meets the esfery standeres set forth in Suboort C of Title 10, code of Federal Reeviations. Port 71. *?ackaging of Radeactive Mate tais for Transport and Transportaten of Radioactive Metenel Under s

Certa.n Cond, tens.-

2.fel This artificate does not relion the eenssonor from complienee with any rooverement of the regulations of the U.s. Desertment of Transoorteten or other asolicebee,eeeutetary.aeoneses, including the government of any country through or into which the package will be tronoported.

3. This certificate is issued on the basis of a safety enssyse report of the package cenign or apoeicetion-3.lal Prepared by (Name and address);

3.tbl Title and identification of report or application:

Hittman Nuclear & Development Hittman Nuclear & Development Corporation, application Corporation dated January 12, 1977, as supplemented..

9190 Red Branch Road Columbia, MD 21045 3.ict ooceet No.

71-9079

~

4. CONolTioNS This certif 6cate is conditsonal upon the fulfillene of the roouirements of Subpart o of 10 CFR 71, as appliceole, and the corusitions spec 6fied in item s below.
s. co.cr

..on os ree <ee.no.no Autnonsed contents, uoo. Numoor. F s.i. Ciaer. oth.r Conditions, and Refer.nces:

(a) Packaging (1) ^ Model Nos.:

HN-100 Series 2 and HN-100 Series 2A l

(2) Description.

A steel encased, le'ad shielded cask for low specific activity material.

The cask is a right circular cylinder 81-1/2 inches high by 81-3/4 inches in diameter.

The. cask cavity is 73-3/8 inches high by 75-1/2 inches in diameter. The cask side wall consists of a 3/8-inch thick inner steel shell, a 1-3/4-inch lead shell, and a 7/8-inch thick outer steel shell.

The base is comprised of two, 2-inch thick steel plates welded together to form a 4-inch. thick base which is integrally welded to the inner and outer steel shells of the side wall.

A steel flange is welded to the inner and outer steel shells of the side wall at the top.

The lid is comprised of two, 2-inch thick steel plates, which are stepped and welded together to mate with the steel flange.

The cask closure is sealed by a Neoprene gasket located between the lid and steel flange, positive closure of the lid is accomplished by eight rachet binders.

The lid contains a centrally located shield plug comprised of two, 2-inch thick steel plates and one, inch thick steel plate stepped and welded.

The shield plug is sealed by a Neoprene gasket, and eight, 3/4-inch studs and nuts are used i

to provide positive closure.

The Model No. HN-100 Series 2 is constructed of A-36 carbon steel.

The Model No. HN-100 Series 2A is constructed of i

A-516, Grade 70, carbon steel.

P00R ORIGINAL 8 =oom.

~

1

]

Page 2 - Certificate No. 9079 - Revision No. 6 - Docket 71-9079 l

(2) Description (continued)

Tie-down is accomplished by four tie-down lugs w ided to the cask body.

There are four cask lifting lugs, three lid lifting lugs, and one shield plug lifting lug. The package gross weight is approximately 48,000 pounds.

(3) Drawings I

The packaging is fabricated in accordance with Hittman Nuclear &

Development Corp. Drawing Nos.: C001-5-9122, Rev. 1; C001-5-9123, Rev.

1; and C001-5-9124, Rev. 1.

(b) Contents (1) Type and form of material i

j Process solids, either dewatered,, solid or solidified, meeting the require-ments for low specific activity radioactive material, in secondary containers.

i (2) Maximum quantity of material per package Greater than Type A quantities of radioactive material with the weight of the contents and secondary containers not exceeding 14,000 pounds.

6.

Shoring shall be placed between secondary containers and the cask cavity to prevent movement during normal conditions of transport.

7.

The lid and shield plug lifting lugs shall not be used for lifting the cask, and shall be ' covered in transit.

8.

Prior to each shipment, the packaging lid seals shall be inspected.

The seals shall be replaced with new seals if inspection shows any defects or every twelve l

(12) months, whichever occurs first.

9.

Packagings fabricated (10 CFR $71.53(c)) after December 18, 1980, shall be constituted of A-516, Grade 70 carbon steel instead of A-36 carbon steel.

l 10.

Optional use of a twelve gauge 304-55 cask interior cavity surface liner is permitted.

l The liner shall be, if used, permanently installed in the cavity and seal welded l

along all edges.

I

11. The package authorized by this certificate shall be transported on a motor vehicle,

, railroad car, aircraft, inland watercraft, or hold deck of a seagoing vessel assigned for the sole use of the licensee.

12.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

1 13.

Expiration date: July 31, 1982.

l 4

l

Page 3 - Certificate No. 9079 - Revision No. 6 - Docket 71-9079 t

REFERENCES Hittman Nuclear & Development Corporation application dated January 12, 1977.

Supplements dated:

June 6 and 21, 1977;~ Septemb'e'r 29, 1978; M'y 9, 1979; and a

March 17 and May 20, 1980.

Nuclear Packaging, Inc. supplement dated December 18, 1980.

FOR THE U.S.- NUCLEAR REGULATORY COMISSION e

Cb,b&

C es E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date: