O Form NRC418 U.S. NUCLEAR REGULATORY CoMMISSloN CERTIFICATE OF COMPLIANCE

,g For Radioactwo Materials Packagne

,1.tal Catificere Numne 1.!b) Revision No.

1.!c) Package identification No.

1.(d) Pages No. 1.(e) Total No. Pages 5908 8

USA /5908/B( )F 1

3

2. PREAM8LE 2.tal This certific..te is issued to satisfy Sectens 171393a.173.394.173.395, and 173.396 of the oopertment of Transporterion Hazardous Materiais Regu6ations (40 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the oeoartment of Transoortation aangerous Cargoes Regulatens (46 CFR 146-149), as amended.

2.th)

The a-*vne and contents desenbod in itern 5 beeow. meets the safety standanss set forth in Suboort C of Tit

10. Code of Fatseres Regulatens. Part 71. "Packagweg of Radioactswa Matenais for Transport and Tronocortation of Radioactrwe Matenal Under Certaan Conditons."

2.fc)

This certificate does not ro6e== the conssysor from cornoeience with any requerement of the regu6atens of the U.s. oscertment of Transoortasson or other acosicense..

v.agences, ancsudirig the government of any cmuntry through or into which the cockage will be tronosorted

3. The certificate a mause on the beans of a safety ensayas report of the onckage doenen or apotication-1(a)

Prepared,by (Narne and address):

3.(b)

Title armi sientification of report or apodicotson:

The Babcock & Wilcox Company Nuclear Materials and Equipment Corporation 609 N. Warren Avenue application dated May 3,1974, as supplemented.

Apollo, PA 15613 71-5908 3,(,3 oo,,,, u,,

i 4 CONosTIONS This certificate es enditamnes upon the fulfillang of the recuerements of Sucoort o of 10 CFR 71, as aco66ceb6e. and the coriditions sceofied in item 5 be6o.

5. Desanouon of Packaging arus Authonzad Contents. Mooel Nurreer, Fissaie Class. other Conditions. and References-(a) Packaging (1) Model No.:

DOT-6M Type B (2) Description Metal packaging as' described and constructed in accordance with DOT Specification 6M (49 CFR 6178.104).

(b) Contents l

(1) Type and form of material l

l (i) Solid radioactive materials which will not decompose at temperatures up to 250*F. Carbide compounds are not authorized; or (ii) U02 or UO2 mixtures in the form of powder or compact pellets; or (iii) Plutonium nitrate or uranyl nitrate solution 'in flame sealed glass ampoules or screw top plastic vials, each within one or more additional plastic vials with taped lids, and within a sealed product can or polyethylene bottle containing a sufficient amount of vermiculite to absorb twice the liquid contents present; or conoo 79 e-

.- +

Page 2 - Certificate No. 5908 - Revision No. 8 - Oocket No. 71-5908 (b) Contents (continued)

(1) Type and form of material (continued)

(iv) Plutonium sources in excess of twenty (20) curies per package must be at least double encapsulated in a metal capsule such that the sources meet special form criteria defined in 10 CFR 571.4(o).

Inner and outer capsules are individually leak tested during fabrication per AWSI N542-1977, procedure A2.2.3 (He pressure bubble test), or equivalent.

(2) Maximum quantity of material per package and fissile class (i) For the material described in 5.(b)(1)(1), the maximum fissile material and maximum hydrogen per package for Fissile Class I is as follows:

Maximum fissile material Hydrogen Material Fissile per package, per package, Material kilograms grams U-235 1.6 20 Pu 0.9*

11 U-233 0.5 6.4

  • Because of the 10 watt thermal decay heat limitation, the limit for Pu-238 is 0.02 kilograms.

Plutonium in excess if twenty (20) curies per package must be in the form of metal, metal alloy or reactor fuel elements.

(ii) For the material described in 5.(b)(1)(i) the maximum U-235 loading for uranium bearing materials with an H/X < 3 and the minimum transport index to be assigned to each package for Fissile Class II is as follows:

Maximum Minimum Kas U-235 Transport Index 4.2 0.1 l

5.4 0.2 1

7.3 0.5 9.1 1.0 (iii) For the material described in 5.(b)(1.'/fi) the maximum quantity of U-233 is 500 grams at an H/U ratio not to exceed 20, as Fissile Class l

III with a limit of 51 packages per shipment. The package size shall not.be less than 55 gallons.

(iv) For the material described in 5.(b)(1)(fii) the maximum quantity of material is not to exceed 20 Ci radioactivity and 40 ml of solution.

Fissile material shall not exceed 10 grams.

(v) For the material described in 5.(b)(1)(iv) the maximum quantity of plutonium is 100 Ci.

l Page 3 - Certificate No. 5908 - Revision No. 8 - Docket No. 71-5908 6.

Two steel through bolts may be installed between the lid and bottom of the steel drums.

7.

Venting may be provided by a 1-inch diameter hole in the drum lid backed by a minimum 1/2-inch thick Cerafelt refractory pad.

8.

Maximum decay heat per package shall not exceed ten (10) watts.

9.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

10.

Expiration date:

February 28, 1986.

l REFERENCES References Required for All Contents Except Contents Described in 5.(b)(1)(iv)

Nuclear Materials and Equipment Corporation application dated May 3,1974.

Additional References Recuired for Contents Described in 5.(b)(1)(fi)

Westinghouse Electric Corporation supplement (WAPD-RS(CC)-620) dated May 8,1973.

DOE, NR supplement dated March 28, 1979.

Additional Reference Required for Contents Described in 5.(b)(1)(iii) and 5.(b)(2)(iv)

Allied Chemical Corporation, Report No. ICP-1061, December 1974.

Reference ?ecuired for Contents Described in 5.(b)(1)(iv)

Monsanto Research Corporation application dated January 10, 1980.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Char es. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date: