ML20003A398

From kanterella
Jump to navigation Jump to search
Annual Rept from Univ of Wa,License R-73
ML20003A398
Person / Time
Site: 05000139
Issue date: 01/30/1981
From:
WASHINGTON, UNIV. OF, SEATTLE, WA
To:
Shared Package
ML20003A397 List:
References
NUDOCS 8102030621
Download: ML20003A398 (3)


Text

._

O Annual Report From the University of Washington Facility License R-73 A.

A Narrative Summary of Operating Experience for the Period January 1, 1980 - December 31, 1980 The University of Washington Nuclear Reactor was operated for 256 hours0.00296 days <br />0.0711 hours <br />4.232804e-4 weeks <br />9.7408e-5 months <br /> (baseline to shutdown) and generated 11,534 KWH of energy.

The 118 experimental runs consisted of sample irradiation for neutron activation analysis, isotope production, laboratory experiments, class demonstrations, anomaly detection experiments, calibrations and operator training.

B.

Unscheduled Shutdowns 1.

At power Date Power Level Cause June 3, 1980 10 kW Telephone receiver accidentally dropped on scram button Sept. 18, 1980 95 kW Safety Amplifier (a)

Oct. 23, 1980 Less than Spike on Log N 10 Watts Nov. 19, 1980 95 kW Safety A=plifier (a)

(a)

Trips result from photodiode isolation falling below operational level due to noise on 110 VAC line.

2.

Not at power December 11, 1979 - January 8, 1980 -- Water accidentally spilled into graphite moderator. Operations were suspended until the reactivity worth of the absorbed water was less than -0.4%

A k/k. Prevention by better orientation procedures plus observa-tion and practice of experimenters.

C.

Corrective and Preventative "aintenance Having Safety Significance 1.

Routine calibration and maintenance as scheduled.

2.

Drying out graphite moderator after accidental spillage of water from reactor top.

(See unscheduled shutdowns.)

u ; o m. 3 0 64 m

o m

(

2 J

D.

Discussion of Changes Carried Out Pursuant to 10 CFR 50.59 1.

None for 1980.

E.

Radioactive Releases to the Environs 1.

Emptied a retention tank (1440 gallons) to sanitary sewer i

February 15, 1980 with total activity less than 0.02 micro-curies and December 12, 1980 with activation less than 0.03 microcuries.

2.

The Argon 41 released to the environments from the facility during 1980 was measured to be 16.7 curies.

i F.

Environmental Surveys Outside the Facility See next page for data available on January 30, 1981.

G.

There were no significant exposures through November of 1980, i.e.,

above 500 mrem. Film badges provided by R.S. Landauer Jr. and Company.

0 i

e

. ~ -,. - -,,,

,<-,m-ry y

y --

c

.?

3 F.

Environmental Surveys Survey by Radiation Safety with TLD and film badges provided by R.S. Landauer, Junior and Company.

Sets were placed at intervals around outside of building.

1.

Data for set dated February which were exposed for month of April, 1980.

Badge No.

Film TLD 39 20 mre.a 40 mrem 40 10 M

41 M

M 42 M

M 43 10 20 44 10 40 45 20 30 46 20 40 47 20 40 49 20 50 f

50 20 50 51 20 40 52 20 40 53 30 60 54 30 40 55 40 70 56 30 40 2.

Data for set dated October which were exposed from October 1, 1980 to December 2, 1980.

l Badge No.

Film TLD 41 M

30 42 20 10 43 M

30 44 20 40 45 M

-10 46 20 30 47 20 20 48 20 40

.