Forwards LER 81-002/03L-0
Date released: 01/17/2020 Download: ML20003A309


LER 81-002/03L-0:on 810107,Unit 1 Emergency Diesel Generator Tripped & Failed to Restart.Caused by Loose Fuse in 125 Vdc Engine Starting & Fuel Control Circuit & Misalignment of Output Breaker Auxiliary Contacts.Fuse Holder Tightened
ML20003A312
Person / Time
Site: Quad Cities 
Issue date: 01/20/1981
From: Mendenhall E
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20003A312 (3)
Forwards LER 81-002/03L-0
ML20003A308
Person / Time
Site: Quad Cities 
Issue date: 01/20/1981
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20003A308 (1)