ML20003A263

From kanterella
Jump to navigation Jump to search
Forwards Supplementary Info Re Spent Fuel Pool Mod,In Support of Installation of high-density Borated Spent Fuel Storage Racks.Info Confirms Structural Integrity of Racks. NRC Concurrence & Revised Safety Evaluation Requested
Date released: 01/17/2020 Download: ML20003A263


Evaluation of Defective Spot Welds in Calvert Cliffs Nuclear Plant High-Density Spent Fuel Storage Racks.
ML20003A264
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 01/12/1981
From: Milos R
NUCLEAR ENERGY SERVICES, INC.
To:
References
Download: ML20003A264 (29)
Forwards Supplementary Info Re Spent Fuel Pool Mod,In Support of Installation of high-density Borated Spent Fuel Storage Racks.Info Confirms Structural Integrity of Racks. NRC Concurrence & Revised Safety Evaluation Requested
ML20003A262
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 01/29/1981
From: Lundvall A
BALTIMORE GAS & ELECTRIC CO.
To: CLARK R A
Office of Nuclear Reactor Regulation
References
Download: ML20003A262 (7)