ML20002E095

From kanterella
Jump to navigation Jump to search
Forwards Proposed Changes to Table 2.3-10 of Fsar,Reflecting Current Instrumentation on Meteorological Tower.Proposed Change Will Be Incorporated Into Next Amend to FSAR
ML20002E095
Person / Time
Site: Farley  
Issue date: 01/20/1981
From: Clayton F
ALABAMA POWER CO.
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 8101260350
Download: ML20002E095 (3)


Text

(O Alabama Power Company 600 North 18th street Post Office Box 2641 Birmingham, Alabama 35291 Telephone 205 250-1000 F. L CLAYTON, JR.

senior Vice President Alabama Power the southem eectnc systen January 20, 1981

~

Docket No. 50-348

'lo. 50-364 Director, Nuclear Reactor Regulation U. S. Nuclear Regulatory Comission Washington, D. C.

20555 Attention: fir. A. Schwencer Gentlemen:

As requested by NRC staff in recent telephone conversations, attached are proposed changes to Table 2.3-10 of the Farley Nuclear Plant FSAR which reflect the current instrumentation on the meteoro-logical tower. This proposed change will be incorporated into the next amendaent to the FSAR. Changes are indicated by a vertical bar.

If you have any questions, please advise.

Yours very truly, k

du F. L. Clayton,(,Jr.

FLC/HRF:de Attachment cc: fir. R. A. Thomas fir. G. F. Trowbridge fir. L. L. Kintner Mr. W. H. Bradford l/

3101260 W Ys

l t

i O

TABLE 2.3-10 (Sheet 1 of 2)

WEATHER INSTRUMENTATION AT FARLEY SITE Approximate Height Above Sensed Recorded Tewer Vase (ft)

Parameter Parameter Instrument Characteristice

-Getund Rainfall Rainfall C11 met Model 0501 Accuracy 1/2% of full scale Grtund Solar Solar Pyrometer (Climet 503-1) - Responds to radiation radiation wave lengths of 0.32 to 2.5 microns 32.8 Wind speed

  • Wind speed Climet Model WS-Oll-1 (speed) - Accuracy and wind and wind of 10.15 mph or 1% of full scale, which-direction direction ever is greater. Response distance con-stant is 5 ft; vane has 1 mph threshold and damping ratio of 0.4.

Climet Model 012-10 (direction) - Accuracy 23 degrees, linearity 21/2% of full scale.

32.8 Horizontal Horizontal Bivane Climet Model 012 Accuracy 3 2

and eleva-and eleva-degrees, linearity 11/2% of full scale tion angle tion angle

' -35 Temperature Ambient EG and G Model 1103-M thermistor in temperature aspirated shield - Accuracy 0.5F over 1

range of 0-100F.

35 Dew point Dew point EG and G Model 1105-M - Accuracy 0.5 F above dew point of -20 F - Response 3 F per second above 32 F.

35 Temperature Reference Matched pair thermistors in aspirated j

for AT solar radiation shield - Accuracy 10.15C.

i 35 Temperature ** Reference Single thermistor in aspirated solar for AT radiation shield - Accuracy 10.15C.

100 Temperature ** T

-T Thermistor in aspirated solar radiation 100 35 shield - Accuracy 10.15C.

i 150 Wind speed

  • Wind speed Same as 32.8-ft level given above.

and wind and wind direction direction 200 Temperature

  • T

-T Thermistor in aspirated solar radiation 200 35 shield - Accuracy 10.15C.

  • Mounted on S.E. side of the tower.

l

.7,

--w-,-

-,.m

=.

g.

TABLE 2.3-10 (Sheet 2 of 2)

Apprcximate Height Above Sensed Recorded Tower Base (ft)

Parameter Parameter Instrument Characteristics e

i 200 Temperature Ambient EG and G Model 110S-M Thermistor in temperature aspirated shield - Accuracy 20.5 F l

over range 0-100 F.

200 Dew point Dew point EG and G Model 110S-M - Accuracy 10.5 F l

above dew point of -20 F - Response 3 F per second above 32 F.

200 Temperature ** T

-T Thermistor in aspirated solar radiation 200 35 i

shield - Accuracy 20.15C.

l

    • 6T aspirators are oriented North.

-