Responds to AEC 740204 Request for Rept Re Postulated Spent Fuel Shipping Cask Drop Accident & Any Proposed Mods. Consultant Engaged & Rept to Be Submitted by 740701
ML20002C792
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 05/01/1974
From: Sewell R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Goller K
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8101100869
Download: ML20002C792 (2)


Text

-

(~

Regulatory Docket Ble Consumci,s

,., c,.

i POWBf typ j

Company a

/p

.. on.c..: :no w..e u.cnia.n A..no.. s.cw.on. Michig.n 49201. Are. Code S17 788-OS50

([

g g

  1. c['[

3 May 1, 1974 n p,,

ch N.0'f n

_.O

$, 7 f *. 1 Re: Docket 50-155 Mr. Karl Goller Assistant Director for License DPR-6

'/

Operating Reactors e' ' /

Directorate of Licensing US Atomic Energy Commission

\\ '.f. '- [';yW Washington, DC 20545

Dear Mr. Goller:

Mr. Donald J. Skovholt's letter of February h,1974 stated that the Big Rock Point FHSR did not explicitly address and evaluate the prob-ability of damage due to a postulated spent fuel shipping cask drop ac-cident and requested that possible damage in the event of a cask drop be evaluated. The letter request further requested that a report of our analysis and any proposed modifications be submitted by May 1,1974.

Consumers Power Company has engaged a consultant to perform the detailed structural analysis necessitated by the February 4, 197h letter.

This analysis will ret be completed until June 197h. We have discussed this with a member of the Directorate of Licensing Staff and stated that we would submit the analysis requested by the February h,1974 letter by July 1, 197h. He agreed with this delay in the requested submittal.

This letter is written to document the extension request such that scheduling of reviews by the licensing staff can be appropriately revised.

Yours very truly, e