Responds to IE Bulletin 80-23, Failures of Solenoid Valves Mfg by Valcor Engineering Corp. Valves W/Parts V70900-21-1 or V70900-21-3 Are Not in Use in safety-related Functions at Facilities
ML20002C713
Person / Time
Site: Peach Bottom  Constellation icon.png
Issue date: 12/10/1980
From: Daltroff S
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-80-23, NUDOCS 8101100775
Download: ML20002C713 (2)


Text

~

'4 sf TL

~

PHILAD ELPHI A ELECTRIC COM PANY

=

2301 M ARKET STREET P.O. BOX 8699 5;'

PHILADELPHI A. PA.19101

'A fh 7

I SHIELDS L D ALTRorp ELacfaic **e Tion December 10, 1980 Docket Nos. 50-277 50-278 IE Bulletin 80-23

I r. Boyce H.

Grier, Director Region I Office of Inspection & Enforcement U.S.

Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406

Dear Mr. Grier:

This letter is in response to Bulletin 80-23 forwarded to us on November 14, 1980, concerning failures of solenoid valves manufactured by Valcor Engineering Corporation.

Approximately 25 manhours have been expended in conducting the review for this Bulletin and in preparing this response.

The

" Action To Be Taken By Holder of Operating Licenses" and our response are stated below.

Action To Be Taken By IIo ld e r o f Operating Licenses 1.

De*, ermine whether V'alcor solenoid valves having P/N's V70900-21-1 or -3 are used to perform any safety-related function at your facility.

...If no such solenoid valves are used, you need only submit a negative declaration to this effect within thirty (30) days of the date of this bulletin and you-need not respond to the remaining items.

(9 8101100 7 7 5 1

" i\\

4

!i r. Boyce H.

Grier Page 2

Response

Our review has determined that Valcor solenoid valves having part numbers V70900-21-1 or V70900-21-3 are not used to perform any safety-related functions at Peach Bottoa, therefore, no response is required for the remaining items in this Bulletin.

Very truly yours,

",/'

f 1

-~,,

i "f.

.. 01

/

o j

cc:

Director Division of Resident and Regional Reactor Insocction Office of Inspection and Enforcement U.S.

!!uclear Regulatory Commission Washington, D.C.

20555