Responds to AEC 721031 Request for Addl Info Re Effects to Improve Leak Detection Sys.Describes Provisions to Improve Process Flow Measurement,Encl Clean Sump Mods,Control Rod Drive Pump Drain Mods & Temp & Dew Point Sampling Sys
ML20002C616
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 03/27/1974
From: Sewell R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Skovholt D
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8101100578
Download: ML20002C616 (4)


Text

0 3

9 w.umg.

In " i p

7

$g*

r

, = =

C0llSumCIS g%.I.'Q gk l

POVlCr O. o,

C0mpEni go

k. w e.. - \\ ~.C 9

{b' / r. ff r 1

.ca

/

91Spu.

YGeneras

.ces: 212 West Michigan Avenue, Jackson. Michigan 49201. Area Code 517788-0550 o %4 March 27, 1974

}

%g}*$/

l 7

.s h

, **bt l

l l

tw 4./

l A

Mr. D. J. Skovholt Re: Docket 50-155 Asst Director for Operating Reactors License DPR-6 l

Directorate of Licensing Big Rock Point US Atomic Energy Commission Washington, DC 205h5

Dear Mr. Skovholt:

By letter dated October 31, 1972 a Technical Specifications change was approved which established allowable identified and un-identified primary system leakage rates at the Big Rock Point Plant.

That letter requested that further information be submitted by March 1974 describing efforts that have been made to improve the leak de-tection system. This letter provides the requested information.

l Early in the design phase of the leak detection system modifications, it was recognized that the process flows could normally i

be handled with the " identified" leakage flows without causing the

" identified" leakage flov limit to be exceeded. Provisions were made to facilitate measurement of these process flows, if required, through installation of leakage trace tees.

l i

A modification was made to the enclosure clean sump to limit its usage to " identified" leakage to insure that no " unidentified" j

leakage could drain to the clean sump. This modification included l

construction of a cofferdam around the clean sump. This dam prevents i

any water that drains on the recirculation pump room floor from enter-ing the clean sump so long as the level does not exceed three inches and the dirty sump level remains below floor level. This dam height is more than adequate to insure that all water accumulating on the recirculation pump room floor vill drain to the dirty sump. The dam i

was successfully leak tested using water at 7/8 inch above floor level.

If water levels in the control rod drive room rise to about l

one to one and one-half inches above floor level, the overflow drainage.

l from the control rod drive room sump would first drain to an adjacent l

floor drain and thence to the dirty sump. Level monitoring equipment on all sumps was installed and would warn of this type of problem 81011005 m N-N

(

Mr. D. J. Skovholt 2

Big Rock Point March 27, 197h should it ever exist. Use of the audio pickup in this room, as sug-gested in our proposed Technical Specifications change dated June 30,-

1972, did not prove practical. The sump and level instrument provide very sensitive detection and measurement.

With the decision to drain all " identified" leakage and process flows to the clean sump, modifications to the control rod drive pump drains were made collecting leakages from their respective relief valves and piston housing and routing these flows.to the clean sump.

Drainage from the pump base remains connected to the dirty sump.

In addition, a permanent drain line was installed for the recirculation pump con-trolled seal leak off collection sink. This line drains to the clean sump.

While all floor drains and equipment drains that might repre-sent " unidentified" leakage drain to the enclosure dirty sump, numerous equipment drains, etc, which represent " identified" leakage still lemain connected to the dirty sump's drain collection system. Where practical, these equipment drains were fitted with leak trace sempling tees which will permit quantitative analysis of these leakages.

This leakage is treated as " unidentified" until identified as to source.

The pipevay coolers act as a condenser under certain atmo-spheric and/or operating conditions. To facilitate measurenent of the condensate from these coolers, a loop seal was installed in the drain along with a leak trace tee.

This arrangement facilitates determina-tion of the source of the condensate.

No floor drain exists in the clean-up demin room. Drainage to the dirty sump was provided by overflow of a two-inch pipe stub. To facilitiate early detection of " unidentified" leakage, two one-quarter inch holes were drilled in the two-inch pipe stub at approximately one-quarter inch from the floor level and a screen was placed around the pipe stub. This arrangement limits the total leakage to approximately 18 gallons before drainage to the dirty sump begins.

To enable more precise identification of leakage sources as well as accurate collection measurements, the dirty sump and the control rod drive room sump, which were interconnected, were separated. This was accomplished.by inserting an expanding rubber plug into the two-inch control rod drive room drain line at the point where it entered the dirty sump. This plug was leak tested with a pressure of about 2h inches of water and no leakage was observed.

With sepan2 tion of the control rod drive room sump from the dirty sump, a sump pump was added to the control rod drive room sump.

The discharge of this pump is routed via a collection basin in the control rod drive pump room to the dirty sump. This arrangement per-1 mits both qualitative and quantitative analysis of leakages from within the control rod drive room.

1 f

i

L.

Mr. D. J.:5kovholt 3

- Big Rock Point March 27,-197h e

Remotely _ located control and level instrumentation were

- installed for the three existing sumps (enclosure clean, enclosure dirty and control rod drive room). This change permits control of

,all the sumps from outside the rec rcu at ng pump room an -con rol i

l i d

t rod drive room. ' Bubbler tube type level instrumentation was also added to each of the sumps and sump level manometers ' (for each sump)_

are located by their respective remote control boxes. Recorders for the enclosure dirty sump level and the enclosure clean sump level vill be installed in the Control Room in the near future.

The following sump pumps have running _ time meters installed to provide. surveillance of water collection rates: The enclosure clean sump, the enclosure dirty sump, the turbine sump and the radvaste sump.

These times are presently lo'gged and reviewed daily to aid in deter-mining water leakage / usage.

A temperature and dev point sampling system has been installed on both the containment supply and the exhaust air ducts. This system is also equipped with a heat exchanger which uses the supply air to cool, the exhaust air which eliminates the temperature limitation of the ref-erence dev point index system used in the pipevay. Data obtained from this system is recorded in the Control Room and has proven to be very sensitive to steam leaks inside containment. The pipevay dev point 4

reference system has proven its sensitivity to steam leaks occurring in the pipevay on several occasions even though it has quantitative limitations as described in our proposed Technical Specifications change dated June 30, 1972. The most recent example was the steam drum level instrument root valve steam leak (December 8, 1973) when a leak of.53 spm (.12 spm in vapor and.h1 gpm as condensate) was detected.

This leakage rate was enough to bring the reference dev point system nearly to its alarm point.

A test procedure (T1-02, Rev 1) was designed to determine the

" unidentified" and " identified" leakage rates using a four-hour measure-ment time. It is intended for use once a day, preferably during the nighttime when water usage is minimized.

Yours very truly,

'h

'wN f f

RBS/mel Ralph B. Sewell Nuclear Licensing Administrator CC: JGKeppler, USAEC

AEC DIE BUTION FOR PART 50 DOCKET MATI

,AL, (TaiPORARY FORM)

CONTROL NO:

2656 b fk i

FILE:

FR0ti:

DATE OF DOC DATE REC'D LTR MDi0 RPT OTHER Con umers Power Company J:ckson, Mich. 49201 Mr. R.B. Sewell 3-27-74 3-29-74 X

TO:

ORIG CC OTHER SENT AEC PDR XXX SENT LOCAL PDA XXX D.J Skovholt 1 sinned CLASS UNCLASS PROP INFO INPUT NO CYS REC'D DOCKET NO:

XXX 40 50-155 DESCRIPTION:

ENCLOSURES:

Ltr re our 10-31-74, furn requested info

~

ACKNOWLEDGED c:ncxrning allowable identified and unidentified primary system leakage rates.....

DONOT REMOVE PLANT NAME:

Big Rock Point FOR ACTION /INFORMATION 3-29-74 JB BUTLER (L)

SCWENCER(L)

/ZIDIANN(L)

REGAN(E)

W/ Copics W/ Copies W/7 Copies W/ Copies CLARK (L)

STOL2(L)

DICKER (E)

W/ Copies W/ Copies W/ Copies W/ Copies COLLER(L)

VASSALLO(L)

KNIGHTON(E)

W/ Copies W/ Copics W/ Copies W/ Copies KNIEL(L)

SCHDIEL(L)

YOUNGBLOOD(E)

W/ Copies W/ Copies W/ Copies W/ Copies INTER"AL DISTRIBUTION

[TfCPDRREG FILE ]

TECH REVIEW DE'iTON A/T IPD W

HENDRIE GRIMES LIC ASST BRAIIMAN SALT 7. MAN

  1. 0GC, ROOM P-506A SCHRDEDER GAS 1ILL
  1. DIGGS (L)

B. M T MUNTZING/ STAFF MACCARY KASTNER GEARIN (L)

CASE KNIGHT BALLADn GOULBOURNE (L)

PLANS GIAMBUSSO PAWLICKI SPANGLER LEE (L)

MCDONALD 0 nE (L)(EWR)

STELI O ENVIRO R D

)

D,70 DEYOUNG(L)(PWR)

HOUSTON MULLER SERVICE (L)

C. MU.ES VSKOVUOLT (L)

NOVAK DICKER SHEPPARD (L)

B. KING P. COLLINS ROSS KNIGHTON SLATER (E)

DENISE IPPOLITO YOUNGBLOOD SMITH (L)

A EG OPR TEDESCO REGAN TEETS (L)

FILE & REGION (3)

LONG PROJECT LDR WADE (E)

MORRIS LAINAS WILLIAMS (E)

STEELE BENAROYA HARLESS WILSON (L)

VOLDIER EXTERNAL DISTRILUTION

'f: /

V T - LOCAL PDR Charlevoix, Mich.

g*

V1 - DTIE(ABERNATHY)

(1)(2)(10)-NATIONAL LAB'S 1-PDR-SAN /LA/NY

  1. 1 - 1.3IC(BUCIWiAN) 1-ASLBP(E/W Bldg,Rm 529) 1-GERALD LELLOUCHE 1 - ASLB(YORE l-W. PENNINGTON, Rm E-201 GT BROOKHAVEN NAT. LAB 1-CONSULTANT' S 1-AGMED(Rtith Gusscani
  1. 16 - CYS ACRS M RIXE Sent to Diggs KEQiARK/BLUME/AGBABIAN Di-B-12 7, GT.

3-29-74 1-CERALD ULRIKSON...ORNL 1-RD.. MULLER..F-309 C'

-.