ML20002B747

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-01B Re Environ Qualification of Class IE Electrical Equipment.Util Enrolled in Sep. Electrical Equipment Qualification Submittals Sent to NRC on 801007,30 & 31
ML20002B747
Person / Time
Site: Big Rock Point, Palisades  File:Consumers Energy icon.png
Issue date: 12/01/1980
From: Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-79-01B, IEB-79-1B, NUDOCS 8012220701
Download: ML20002B747 (1)


Text

,

CORSumBfS I

21 4

g POW 8i o

t C0mp20Y E

e

=>

~

, ~. ~

Generet Offices: 212 West Michigan Avenue, Jackson, M6chigan 49201 * (5171 788 4550 75

'(( g Q

JS

?Ei December 1, 1980 A

.O j m Mr James G Keppler Office of Inspection and Enforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKETS30-135 AND 30-233 - LICENSES DPR-6 AND DPR BIG ROCK POINT AND PALISADES PLANTS -

RESPONSE TO IE BULLETIN 79-01B - ENVIRONMENTAL QUALIFICATION OF CLASS lE ELECTRICAL EQUIPMENT IE Bulletin 79-01B, dated February 9, 1979, along with its subsequent supplements required us to address your questions on environmental qualification of Class 1E electrical equipment for both our Big Rock Point and Palisades nuclear facilities.

Consumers Power Company is involved in the SEP program for both our operating Plants and is meeting the requirements of the subject bulletin through electrical equipment qualification (EEQ) submittals to the NRC on October 7, 1980 and October 30, L980 (Rev 1) for the Palisades Plant and October 31, 1980 for the Big Rock Point Plant.

Our letter dated November 26, 1980 provided our understanding and actions to be taken with respect to the latest h7C Order on EEQ (dated October 24, 1980) to modify the operating license of both Plants.

We believe that the actions we are taking to address the EEQ issue meet the NRC requirements and since both the Palisades and Big Rock Point Plants are in the Systematic Evaluation Program, separate specific responses to IE Bulletin 79-OlB and its supplements are not necessary at this time.

m_o David P Hoffman Nuclear Licensing Administrator CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement NRC Resident Inspector-Big Rock Point STC Resident Inspector-Palisades DEC 319go 7d/

8012220

_._.