ML20002B733
| ML20002B733 | |
| Person / Time | |
|---|---|
| Site: | River Bend |
| Issue date: | 09/19/1980 |
| From: | Draper E GULF STATES UTILITIES CO. |
| To: | Seyfrit K NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| IEB-79-03A, IEB-79-3A, RBG-8624, NUDOCS 8012220669 | |
| Download: ML20002B733 (1) | |
Text
/4C
",, Q $10il
_.. i ma uh
~~
~ _ '
MG DJl 28 Rt 1 04 GUEaF STATES UTILITIES COMPANY g g#0sT o n wie s e O 4 2951 *OEAUMONT TEXAS 77704 C31 i!0S $ERVICES AREA CODE 713 838 3943
- a ASC!!
September 19, 1980 RBG - 8624 File Nos. G9.5, G9.33.1 Mr. K. V. Seyfrit, Director U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive Suite 1000 Arlington, TX 76011
Dear Mr. Seyfrit:
RIVER BEND STATION - UNITS 1 AND 2 REFER TO: RIV DOCKET NOS. 50-458/IE BULLETIN NO.79-03A 50-459/IE BULLETIN NO.79-03A This report is the supplement referred to in our letter of August 5, 1980, which provided a negative response to our A/E's (S&W) scope of supply for I&E Bulletin 79-03A. Our NSSS (GE) vendor has indicated that SA-312 or A-312, Type 300 Series fusion welded pipe used in safety-related systems are not subject to stresses greater than the 85 percent of the Code allowable stresses. This negative dec-laration concludes all other applications, reports, or CLP examination l
reports required by I&E Bulletin 79-03A.
Sincerely,
$ ^ ?= YWhy E. Linn Draper, Jr.
Vice President - Technology l
cc: NRC Office of Inspection & Enforcement Division of Reactor Construction Inspection Washington, D.C.
20555 l
8012220 M Q