ML20002A785

From kanterella
Jump to navigation Jump to search
LER 80-057/03L-0:on 801004,PCRV Pressure Exceeded Penetration Interspace Pressure.Caused by Malfunction of Pressure Switch.Pcrv pump-up Terminated & Switch Linkage Retightened & Calibr
ML20002A785
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 10/31/1980
From: Gahm J
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20002A783 List:
References
LER-80-057-03L, LER-80-57-3L, NUDOCS 8011210552
Download: ML20002A785 (1)


Text

-

4 P+ *>

' D RCN POR4A 386 U.S. NUCLEAR REtULAT%Y COfitelSSION Wm ~ ,,

LICENSEE EVENT REPORT l l l (PLEAss PRINT OR TYPE ALL REQUIRED INFORMATIONI CONTROL sLOCx: l i

l l o@

[oTilaeI C101 ri Si vi 11@is0101 -1010101 c,101 - 1010 2n

@l 411l t l 2 I 0 igiu uCENst TvPE 40 i

CAT se ig i i4 uCENsE NuueER 2e i uCENsEE CoOE i CCN'T lolil Eq',"c'lL)@[0!Sl010l012l'6l71@l1 64 99 10EVENT 10 DATE14 l8 10 l@l110l3l119l0l@

74 7s REPORT OATE do 8 8 60 61 DOCKET NuusER EVENT DESCRIPTION AND PROSA8LE CONSEQUENCES h A 1 At 1100 hours0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br /> on October 4,1980, with the plant operating at 7% thermal power, PCRV l FTTl I pressure exceeded penetration interspace pressure due to malfunction of the pressure f l o 4 l switch controlling interspace pressurization. This constitutes a degraded mode of I t o i s ; i a 4.2.7 and is reportable per Fort St. Vrain Technical Specification AC 7.5.2(b)2. [

t o is l l Mo accompanying occurrence or probable consequences. No affect on public health or l l

l o I 7 I I safety.

l 10181 l 80 l E OE susc E COMPONENT CODE sus COE su E Loj,,9J IC IJ lh [Ejh [Ej@ l I l N l S l T l R l U lh l S lh (1,j h 13 18 19 20 7 8 9 10 It 12 REPORT REVISION sEcufNTtAL OCCU R R E NCE EVENTYEAR REPORT No. CODE TYPE N O.

i O a'E L

suv'egR'RO

,,,. l218122 l l-l 23 1015171 24 26 W

27 10131 28 29 It I 30 b31 101 32 K N AC C O T WE HCuRs sei POR S. PL MA uPAC RER I zlO 101010101 v_J L1]@ INi@ 131213l5t@

l22E!@L.zJ@ LzJ@

2 as

2. ai .o L.i @ 42 2 o .,

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

l i j o l l A Mercoid pressure switch, model DA-23-3, failed to perform its intended function in l f

g (monitoring PCRV penetration interspace pressure due to loose linkage on tFie Bourden tube connection to the switch. PCRV pump-up was terminated, the switch linkage was l

,,,,, g retightened, and the switch caliSrated per approved precedure. Proper pressure dif- l g

ferential was re-established.  ;

ao 7 s e TA  % POWER OTHER status t O R OlsCOVERY OEsCRIPTeoN h

! i I e I [,,,,,C,j@ l 01 0 l 7 lhl N/A l

++

l Whl

  • s Personnel as Observation /Investi2ation ao 7

Sg cag, 12 n-i LOCATION OF RELEASE @

1 6 RELEAsEo@08 RELEasEgl Amount N/A oF Activity @l lN/A l PERsONNEi ExPosu5Es Nuw.eR l' t l' 7' l 1010 '

l 0 lhlTvPEZ

N/A lh(DEsCRirTiCN@ '

l

,ERso~NE't i,uuks NuweER QEsCRimONh  !

y l 0 l 0 l 0 l@l N/A 80 l

7 8 9 11 12 -

l Loss OF CR OAMACE TO PACILtTV l TYPE DESCRIPTION N/A l l

'It191 W hlto so  !

7 a e .

NRC USE ONLY ,

issut DE CRimCNh 7

2 o 8 9 hl to N/A , .  !

68 69 lIIllll1IIlI15 30 -

PHONE: (303) 785-2253 g NAME OF PREPARER ,-

8011210552

- .. - - .