_, .._-__ _ _ , _ ,

U. S. NUCLEA3 CEIULATEY COMRAISSION WecPORM ms

. a.m : '

  • -
  • LICENSEE EVENT REPORT O.-

CONTROL SLOCK: l 1

l -l l l l lQ 6

(PLEASE PRINT OR TYPE ALL REQUIREO INPORMATION) l 01 0 I l@

fo'Til 7 8 9I CI'01 UCENSEE FICoot si vi 11@1501 01uCENSE to -l 01NuMcER 01 O! 01 01@ 84 uCENSE 25 2 I il il TYPE 21 JO Ol@l5/ CAT 68 CON'T loi1I s ay l LQl0 l5 l0 l0 l0 l2 l6 17' @l1 88 69 l0 10 13 l8 l0 @l1 EVENT oATE 74 75 l0 lREPoRToATE 3 l1 l 8 l0 80l@

f 8 60 61 DOCKET NUMSER EVENT DESCRIPTION AND PROSASLE CONSEQUENCES h i

Q l On three separate occasions between October 3.1980, and October 13J980, the plant 3 l was operated with individual snubbers out of service for corrective / preventive mainte-f f7TT1 I nance. Although snubbers were operable prior to removal from service, this is inter- l f3 TT1 1 preted as degraded mode of LCO 4.3.10, reported per Fort St. Vrain Technical Specifi- [

[5 Tin l cation AC 7.5.2(b)2. No affect on public health and safay . No accompanying occur- [

lol7l lrence or probable consequences. No similar reports. l I

Io Ie i I ,,

  • sW ?o"# suTME Ceu,o~E~TCoat su'.E'a E sE/of -

Io191 l Xl Xl@ [X,_j@ [,z,,,,J @ l S l U l P l 0 l R l T lh lD lh20 W@

18 is 7 8 9 10 11 12 13 OCCURRENCE REPORT REVfSION SEcufNTIAL EV ENT YE AR REPORT No. CooE TYPE No.

LER

@ ,asg/Ro l8 l0 l [_-j l 016111 lel 10 l 3 l ltl [-j [,0_J u 24 28 27 28 29 Jo 31 J2 21 22 23 KN ACT o oP T ME HOURS SS iTT PoR S. s'U ( MA UF C RER lXl@lzl@ .lzlg

- 33 J4 35 W @

36 l0 l0 l0 l0 l 37 40 W@ lN l@ lAl@

el 42 43 lIl2l0l7lh 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l_i_ l o l l ITT Grinnell snubbers which were operable while in service were removed from service 1

, , , for corrective / preventive maintenance to assure continued operability. One snubber i reservoir filled with oil, one adjusted to avoid interference, and one adjusted to j l assure continued oil supply to snubber. No change in surveillance interval reqtiired. I I

L.' 1.* I I 80 F 8 9 ST  % POWER ETHER STATUS o15 o Y otscovERY DESCRIPTION h g j'C l@ l 0l 0l 4l@l N/A l ]@l Review of Logs l ACTiv TY Co'0 TENT tocaTioserRELEAsEh MELE Asto or aELEAst AmousTor Activity @ ll N/A l

~'

l,,i_l,6,j' *

[zj@ Q'l N/A '

. PERsommEL Exposures

~u..ER Tv,E onCR,,Tio~@

N/A l E I 0' l' O l o l@Lz_J@l" *

,ERscu~E'ubuLs

~u E R onCRi,Tio=@

l l- L' La.J s9 l o l o l. o11 l@l12 N/A so

! 7 .

t or o cauac To FAClufy t

l Lu,,9J LzJ@l N/A -

30 7 8 9 10 NRC USE CNLY 77 PVOLICiTY l

l 2 o TJf@f"'"g' ~ sonno i i , iiiiiii,,,ij AME OP PREPARER PHONE: (303 785-2223 -

e: -