GNRO-2019/00052, Report of Changes and Errors to 10 CFR 50.46 Analysis

From kanterella
(Redirected from ML19354A508)
Jump to navigation Jump to search
Report of Changes and Errors to 10 CFR 50.46 Analysis
ML19354A508
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 12/13/2019
From: Emily Larson
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GNRO-2019/00052
Download: ML19354A508 (2)


Text

GNR0-2019/00052 December 13, 2019 Entergy Operations, Inc.

P.O Box 756 Port Gibson, M1ssl8Slpp1 39150 Eric A. Larson Srte Vice Presldent Grand Gulf Nuclear S!atlon Tel 601-437-7500 10 CFR 50.46 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

REFERENCES:

2019 Report of Changes and Errors to 10 CFR 50.46 Analysis Grand Gulf Nuclear Station, Unit 1 NRC Docket No. 50-416 Renewed Facility Operating License No. NPF-29

1. Entergy letter to NRC, GNR0-2018/00046, "2018 Report of Changes and Errors to 1 OCFR50.46," dated October 16, 2018 (ADAMS Accession No. ML18290A536).

In accordance with 10 CFR 50.46(a)(3)(ii), Grand Gulf Nuclear Station, Unit 1 (GGNS), is required to report to the Nuclear Regulatory Commission, at least annually, the estimated effect on the limiting Emergency Core Cooling System (ECCS) analysis caused by changes to, or errors discovered in, the acceptance ECCS evaluation model.

In Reference 1, an error in the Loss of Coolant Accident (LOCA) analysis was reported.

Specifically, the lower limit for the control rod guide tube to control rod drive housing interface backward leakage path was not implemented correctly. General Electric Hitachi (GEH) has performed an evaluation and demonstrated that there is no impact to the calculated peak clad '

temperature (PCT) associated with this error. The current Licensing Basis PCT for GGNS is

<1730 degrees F. This is below the 2200 degrees F acceptance criterion of 10 CFR 50.46.

GN R0-2012/00052 Page 2 of 2 This letter contains no new commitments. Should you have any questions or require additional information, please contact Jim Shaw at 601-437-2103.

Sincerely, Eric A. Larson EAUfas

Attachment:

None.

cc:

NRC Region IV - Regional Administrator NRC Senior Resident Inspector, Grand Gulf Nuclear Station NRR Project Manager