Text
e e..
VIRGINIA ELECTRIC AND POWER COMPANY RJ(CHMOl'TD, VJi:ROIN XA 23261 July,26, 197S:
- 11r. James P. O'Reilly~ Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Region II - Suite 818.
230 Peachtree Street 3 Northwest Atlanta~ Geo.rgia 30303 :
Dear Mr.* 0' Reilly:
Serial No. llSC/022178*
PO&M/DLB:das Docket*
-280
5-6~8}~=----
License ~o~
R-32 DPR-3T::
This is in respon~e*to IE Bulletin 73:..04,. "Environmental Qualification of Certain Stem Mounted Limit.- Switches Inside Reactor Containment".,
At the time of our or.iginal response to this bulletin, dated March 22,. 1978*~ the information requested was not available for Surry Power StationUnit Nos; 1 and 2.
In that submittal we connnitted to perform a survey for these limit switches at the next outage on each unit:&
This survey' ha;'now,been: completed for Surry Unit Nos. I and 2~. Namco Nadel D2400X limit switches were found, to* be in use on three(3r valves on safety related equipment in each c.Ontainment.* In each case these limit switches are on letdown orifice isolation valves.' 'Each unit has 3 *such valves, located in parallel, which are used to select ;the'proper letdown orifice(s) ta use for various ope.rational modes.
These valves also serve*as contairnnent isolation valves.
Our correc.tiv.e a~ti~ri: will be to replace the subject limit switc~hes with qualified switche~. and to locate the "latch in" relays outside containment.*
- This action is contingent 'upon the availability of qualified materials.
Our tentative schedule is to -c~~plete. these changes* at. the next*. refuel=i:ng on each unit.
Ve1:y truly yours,.
µ~
C. M. Stallings Vice President *- Power Supply and Production Operations cc:.* U. S. Nuclear Regulatory Commission Office of-Inspection and Enforcement Division of Reactor Operations Inspection
- . Washi;ngton, D. c.
20555