g c#

'e,,

UNITE 3 STATES 3%

i' NUCLEAR REGULATORY COMMISSION

./h

}-

REGION tv s

$11 RYAN PLAZA DRIVE. SUITE 1000

[ g.

%....8 g

ARLINGTON. TEXAS 70011 s

-i Q&

April 28, 1981

. -4v,3' q

u v

MEMORANDUM FOR: Those Listed Below FROM:

W. C. Seidle, Chief, Engineering Inspection Branch

SUBJECT:

REPLY - IE BULLETIN NO. 80-21

'.e reply to IE Bulletin No. 80-21 from Houston 1.ighting and Power Com; iny (South Texas Project, Units 1 and 2) is attached for your information.

f

$^

f T

}

W. C. Seidib Chief Engineering Inspection Branch j

Attachment:

Letter dated January 5,1981, G. W. Oprea, Jr., to Karl Seyfrit Distribution:

IE Files MPA/DTS NRR/DPM NRR/ DOR l

sf/4 }i 1

6 8106020 % 4

The Light COE%f Houston Lighting & Power P.O. Box 17no Houston, Texas 77001 (713) 228-9211 l

January 5, 1981 ST-HL-AE-594 SFN: V-0540 A

d Mr. Karl Seyfrit Director, Region IV Nuclear Regulatory Comission

?

611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012 Cear Mr. Seyfrit:

South Texas Project Units 1&2 Occket Nos. STN 50-498, STN 50-499 Interim Recort on IE Bulletin No. 80-21 Bulletin No. 80-21, received November ~10,1980 is being reviewed by Houston Lighting & Power Comoany. Thus far, no valves planned for use in safety-related systems have been identified as being constructed of parts cast by Malcolm Foundry. However, to allow all safety-related valve sup-roject to effectively evaluate this concem, a pliers for the South Texas o report will be submitted to your office by Febraary 17, 1981. This report will fully close this concern if no Malcolm Foundry parts are found or will describe any necessary actions taken per the recuirements of the subject bulletin if Malcolm Foundry parts have been found.

Very truly yours,

, p[,

}

!ljlm.WirftrT' F

Executive Vice President TAP /mmf ir

g Houston Lighting & Power Company January 5 1981 ST-HL-AE-$94 SFN: V-0540 cc: Ofrector, Division of Reactor Construction Inspection Office of Inspection and Enforcement i

Nuclear Regulatory Commission M. D. Schwarz (Baker & Botts)

R. Gordon Gooch (Baker & Botts)

J. R. Newman (Lowenstein, Newman, Reis, Axelrad & Toll)

J. H. Goldberg D. G. Barker A. J. Granger R. A.'Frazar G. B. Painter R. L. Waldrop H. R. Dean C. L. McNeese p

I I-r

. '