Text
pok 01-W "I GENER AL $ ELECTRIC NUCLEAR ENERGY BUSINESS GROUP GENERAL ELECTRIC COMPANY 175 CURTNER AVE., SAN JOSE. CALIFORNIA 95125 SPENT FUEL SERVICES OPERATION DMD-520 Docket No. 71-9001 February 6, 1981 6'
U.S. Nuclear Regulatory Co nmission Ig pC g
Office of Nuclear Material Safety and Safeguards g
jS g
O Division of Nuclear Fuel Cycle and Material Safety y4 g8/g,[2 Attn:
C.E. MacDonald, Chief p
Transportation Branch 7A
%, p Washington, D.C.
20555
'g C
SUBJECT:
GENERAL ELECTRIC IF-300 SHIPPING CASK DOCKET N0.
CERTIFICATE NO. 9001, REV 11; GROUP II FUEL AMENDMENT Gentlemen:
General Electric requests an amendment to Certificate of Compliance 9001, Rev 11 for the IF-300 spent fuel shipping cask. This amendment would 1) pemit the transport of Group II (8x8 BWR,16x16 PWR and 17x17 PWR) fuel bundles in either the wet or dry shipping mode in the IF-300 cask, 2) reduce the fuel rod pressure limits on BWR fuel for wet shipments and 3) clarify the identity of nuclear safety related (Basic) con.ponents of the IF-300 cask.
The supporting information and analyses for this amendment request are in the attached Consolidated Safety Analysis Report (CSAR), NED0-10084, Revision 2C package that includes the following items:
- 1) A complete revision to the Criticality Analysis (Chapter VII) that covers all BWR and PWR fuels for IF-300 transport,
- 2) A new appendix to the Structural Integrity Analysis (Chapter V) that analyzes accident loadings on Group 11 fuels,
- 3) A partial revision to the Thermal Analysis (Chapter VI) to include Group II fuels,
- 4) A partial revision to the Fission Gas Release analysis (Chapter IX) to include Group II fuels, THIS DOCUMENT CONTAINS POOR QUAUTY PAGES 18457
!830226OOK g,
d GENER AL $ ELECTRIC
- 5) Revisions to the IF-300 cask licensing drawing 159CS238 that document the changes listed in Table 1 (attached),
- 6) An added section to Safety Compliance (Chapter-X) to clearly. identify nuclear safety related (Basic) components,
- 7) Clarification of neutron measurement requirements for dry fuel shipments in the Shielding analysis (Chapter VIII),
- 8) Addition of Revision L of the Target Rock Valve drawing 73J-001, and
- 9) The deletion of the obsolete Quality Assurance Plan Summary, (AppendixIX-1).
If this requested amendment is granted, the revised items of the Certifi-cate of Compliance might read as follows:
l 5(a) Packaging.
(4) Basic Components
't The Basic Components of the IF-300 shipping cask that are important to nuclear safety are listed in Sub-section 10.5.
(b) Contents-water as primary coolant 4
(i) - Gro~ p I fuel assemblies u
PWR BWR Fuel form Clad U02 pellets Clad U02 pellets Cladding material Zr or SS Zr or SS Maximum initial U 465 198 content / assembly, kg Maximum initial U-235 4.0 4.0
-enrichment, w/o Maximum bundle cross 8.75 5.75 section,-inches Fuel pin array 14x14/15x15 7x7 Fuel diameter, inch' 0.380-0.460 0.500-0.600 Fuel pin pitch 0.502-0.582 0.647-0.809 range, inch-Maximum active fuel
-145 146 length, inches 4
PWR assemblies may be shipped with or without control rods. -Partial'~ fuel assemblies, that is, assemblies-s
= ~
from which fuel pins are missing, may not be shipped unless~ dummy fuel pins 'are used to dispTace an amount of water equal to that displaced by the original pins.
GENERAL $ ELECTRIC
. (ii) Group II fuel assembliss PWR BWR Fuel form Clad U02 pellets Clad U02 pellets Cladding material Zr or SS Zr or SS Maximum initial U 475 198 content / assembly, kg Maximim initial U-235 4.0 4.0 enrichment, w/o Maximum bundle cross 8.75 5.75 section, inches Fuel pin array 16x16/17x17 8x8 Fuel diameter, inch
.475.505
.376.400 Fuel pin pitch range,
.630.645
.496.507 inch Maximum active fuel 150 146 length, inches PWR assemblies may be shipped with or without control rods.
Partial fuel assemblies, that is, assemblies from which fuel pins are missing, may not be shipped unless dummy fuel pins are used to displace an amount of water eaual to that displaced by the original pins.
(c) Contents - air as primary coolant (1) Group I fuel assemblies
-PWR BWR Fuel form Clad U02 pellets Clad 002 pellets Cladding material Zr or SS Zr or SS Maximum initial U 465 198 content / assembly, kg Maximum initial U-235 4.0 4.0 enrichment, w/o Maximum bundle cross 8.75 5.75 section, inches -
Fuel pin array 14x14/15x15 7x7
-Fuel diameter, 0.380-0.460 0.500-0.600
' inch l
Fuel pin pitch, 0.502.0582 0.647-0.809
~
range, inch
Po GENERAL $ ELECTRIC 1 1 PWR BWR Maximum active fuel 145 146 length, inches The assemblies may be shipped with or without control rods.
Additional fuel pins secured in guide tube thimble may be shipped. Partial fuel assemblies, that is, assemblies froe which fuel pins are missing, may not be shipped unless dummy fuel pins are used to displace an amount of water equal to that displaced by the original pins.
. ii) Group II fuel assemblies
(
PWR BWR Fuel form Clad U02 pellets Clad UO pellets 2
Cladding material Zr or SS Zr or SS Maximum initial U 475 198 content / assembly, kg Maximum initial U-235 4.0 4.0 i
enrichment, w/o Maximum bundle cross 8.75 5.75 section, inches Fuel pin array.
16x16/17x17 8x8 0.475-0.505 0.376.0.400 Fuel diameter,.
inch Fuel-pin pitch, 0.630-0.645
-0.496-0.507 range, inch Maximum active fuel 150 146 length, inches PWR assemblies may be shipped with or without control rods.
Partial fuel assemblies, that is, assemblies from which fuel pins are missing, may not be shipped unless dummy fuel pins are used to displace an amount of water equal to that displaced by the' original pins.
.6.(a) For contents 5(b) the end of life (after irradiation) cal-culated fuel pin pressure shall not exceed 1,800 psia at 900*F for PWR fuel and shall not exceed 900 psia at 900 F for BWR fuel.
~ _.
(
-.....----...u
~. - -
s.- - - - -
---u-----
GENERAL $ ELECTRIC
, Enclosed is a check for $6900 as prescribed in Part 170.31(ll)( A) for major amendments.
General Electric requests that the review of this amendment may be completed by August, 1981.
Respectfully submitted, GENERAL ELECTRIC COMPANY
[
-v<s_
D.M. Dawson, Manager Licensing & Transportation DMD:LEF:bn Enclosure - Check for $6900
i TABLE 1 Changes to GE Drawing 159C5238 1.
Sheet 1
- relocated batteries, added bails to valve box covers, showed panel swing.
2.
Sheet 2 - showed panel s.;ing, deleted type of Aluminum.
3.
Sheet 3 - changed note 2.
4.
Sheet 4 - changed connector identity, changed callouts on screws, added ba'.is to box covers.
5.
Sheet 5 - changed Grayloc seal callout, changed 30455 to 300 series SST on several small items, modified guidepin, added bails to valve box covers.
6.
Sheet 7 - added plate detail. Added spacer ass'y view, changed 30455 to 300 series, added bails to valve box covers.
7.
Sheet 8 - identified IF-300 piping, changed 30455 to 300 series.
8.
Sheet 9 - revised skid tiedown details, added expansion tank.
l l
I