Part 21 Rept & First Interim Deficiency Repts Re Standby Gas Treatment Design Deficiency,Initially Reported 801212.Final Rept Expected by 810529
ML19351F843
Person / Time
Site: Hartsville, Phipps Bend  
Issue date: 01/09/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-81-351-000 10CFR-050.55E, 10CFR-50.55E, PT21-81-351, PT21-81-351-000, NUDOCS 8102200342
Download: ML19351F843 (2)


Text

.

% ne PART 21 IDSTIFICATIbN NO. ti-%-om CU PANY lia'E w % ho.A-s D4E OF LETTFA \\\\;hs DJOEI IO. U -6er %' 57.6 Miik-%

E DATE DISTRIBUTED t\\2.o6t ORIGIt!AL REPORT j__

SLPPLB BiTARY o.m.

DISTRIBUTION:

REACTOR (R) )(

FLEL CYCLE &

SACEC41ARDS (S) a yg.

l'ATERIALS OD IEFILES EES IE FILES AD/SG AD/FFFSI AD/ROI EGIONS I,II,III,IV,V PEGIONSI,II,III,IV,V REGICNS I,II,II!,IV,V

\\SOJR BR. R-IV

\\$ EOR BR. R-IV VS O2R BR. R :

LDE3 / FPA FIG 5715 ff SS / FGS SS-395 NRR/D3L EOD FIG 7602 LDEB/FPA f,46 5715 IOSS / SG SS-881 N?NDOE ACOD FIG 7E02 LDEB / tPA FIG 5715 NRR/DSI ASLEP E/d 450 AEOD FIB 7672 IA#

SA /SP fig-7210A ASLBP E/W 450 NRR/ DOL ICSUP L FILES 016 CBiTRAL FILES 016 ASLBP Erd 450 CSKRR FIE ( GEO CBHPALFILES (GF00 CSERALFILES 016 PDR CBiTPAL FILES SS-395 CBJRAL FILES (dip 30 LPDR PDR

\\,b, W, gQts i

~

PDR H

N

[E)R IBAli, g ou- _ g., e 'C k y

j S (:

.?

\\t.,\\ s.q y'

y. :

ACTID'h 0,..

,e

/_ [Tne ' V' PRELIMIfWlY EVALUATION OF THE' ATTACHED REPORT ItOICATES LEAD RESPONSI[

FOLLOWJ? AS SFOhN BELOW:

IE y_

NRR[

FESS [

OlliER EES 810 220 032gm Pa' 8/1/80 4,W iddu

bb h2 I"

st TENNESSEE VALLEY AUTHORITY CH ATTANOOG A. TENNESSEE 37401 400 Chestnut Street her II January 9, 1981 HrRD-50-518, -519, -520, -521/80-03 PERD-50-553, -554/80-03 Pr. James P. O'Beilly, Director Office of Inspection ard Enforce:nent U.S. Ibclear Pegulatory Com:rlssion Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

IPRISVILLE RD PEIPPS BRD NJJEEAR PL76'IS - 57?S DESIG; DEFICICCY -

ErRD-50-518, -519, -520, -521/80 PBBD-50-553, -554/80-03

'Ihe sdject deficiency was initially repor*ced to IGC-CIE Pegion II Inspector ftKenzie 'Ihcras on December 12,1980, as n's H2 ANES 8004 and PaNEB 8004.

In conpliance with oaragraph 50.55(e) of 10 CFR Part 50, we are enclosing the first interim report on the subject deficiency. Ye consider 10 CFR Part,R1,

' applicable to this nonconformance. 'IVA anticipates transmitting the final renart on or before May 29, 1981.

If you have any q2estions, please call Jim Dcrer at FIS 857-2014.

Very truly yours, THNESSEE WilEY AUIHORITY L. M. Mills, Fanager Ibclear Regulation ard Safety Enclosure cc: Mr. Victor Stello, Director Office of Inspection and Enforcenent U.S. Ibclear Regulatory Cartission Washingban, DC 20555 An Equal opportunity Employer