f0 jg 3 C

j,,, tes'plW'jj, f I

, December 30, 1974 Mr. R. H. Engelken, Director Directorate of Regulatory Operations Region V U. S. Atomic Energy Commission 1990 N. California Boulevard Walnut Creek Plaza, Suite 202 Walnut Creek, California 94596 Re:. Docket No. 50-133 License No. DPR-7 Humboldt Bay Power Plant Unit No. 3

Dear Mr; Engelken:

This is to confirm a telephone conversation on December 28, 1974 between Mr. W. A. Raymond, Plant Superintendent, Humboldt Day Power Plant, and Mr. W. G. Albert of your office in which Mr. Raymond described a condition concerning the conductivity of the reactor water during the startup of No. 3 Unit.

During the startup of Unit No. 3 on December 26 & 27, 1974, reactor uater conductivity increased to 11 p mho/cc as measured immediately after start-up.

This execeds the absolute limit of 5 p mho/cc but is permitted by the te'chnical specifications which state in Table IV-2 Note (3) "the conductivity absolute limit may by exceeded for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after any startup." The conductivity was decreased steadily during the period following startup. However, it did not reach 5 p mho/cc until 24-1/2 hours had clapsed. Therefore, the technical specification limit was exceeded for a period of approximately 30 minutes. All other water quality values were within the absolute limit during the entire period.

Chloride ion concentration at the end of the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period following startup was 0.051 ppm.

Chloride ion operating limit is 0.1 ppm and absolute limit is 0.5 ppm.

This is being reported under Section IX.H.2.a.(2) of the technical specifications.

Very truly yours,,

I q

a@fv5G. Th G

t

  • G#s a ci o?

si s9'/

G B

h

_.,.. ~..