LER 80-037/03L-0:on 801207,RHR 2D Pump Inoperable Due to Excessive Leakage of Mechanical Seal.Caused by Normal Wear of O-ring Sealing Surface.Mechanical Seal Replaced.Pump Returned to Svc & Satisfactorily Tested
ML19351F631
Person / Time
Site: Quad Cities 
Issue date: 12/29/1980
From: Mendenhall E
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19351F631 (2)
Forwards LER 80-037/03L-0
ML19351F627
Person / Time
Site: Quad Cities 
Issue date: 12/29/1980
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19351F627 (1)