ML19351E751

From kanterella
Jump to navigation Jump to search
Thermal Hydraulic LMFBR Safety Experiments, Monthly Highlight Ltr for Oct 1980
ML19351E751
Person / Time
Site: Clinch River
Issue date: 10/31/1980
From: Ginsberg T
BROOKHAVEN NATIONAL LABORATORY
To: Silberberg M
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
CON-FIN-A-3024 NUDOCS 8012190161
Download: ML19351E751 (4)


Text

TNTERIM REPORT Accession No.

Contract. Program or Project

Title:

Thermal Hydraulic LMFBR Safety Experiments Subject of this Document:

October Monthly Highlight Letter Type of Document:

Monthly highlight Intter Author (s):

Theodore Ginsberg and others Date of Document:

October 1980 Responsible NRC Individual and NRC Office or Division:

Dr. Melvin Silberberg Division of Reactor Safety Research U.S. Nuclear Regulatory Commission Washington, D.C.

20555 This document was prepared primarily for preliminary or internal use.

It has not received full review and approval.

Since there may be substantive changes, this document should not be considered final.

l Brookhaven Naticnal Laboratory Upton, New York 11973 Associated Universities, Inc.

for the U.S. Department of Energy Preparea for U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Under Interagency Agreement DE-AC02-76CH00016 -

FIN A-3024 l

NRC Rasmch e. in mu,,

J c, ~.

m..

n f

D

t Monthly Highlights for October, 1980*

Thermal Hydraulic LMFBR Safety Experimentt Experimental Modeling Group Department of Nuclear Energy Brookhaven National Laboratory Upton, New York 11973

  • Work carried out under the auspices of the United States Nuclear Regulatory Commission.

p{n.

8 3 5 dd -

v i

<ij

} 4 j ;[*[1 e

a bbib(bkICOf(f)jfUjl

i 1

.f

~ 1.

  • Thermal Hydraulic LMFBR Safety Experiments l.1 Dispersion in Internally Heated Boiling Pools (T. Ginsberg, H. Makowitz)

Work continued on preparation of the report on the feasibility of usin8 microwave heating in boiling pool studies. A first draft is nearly complete.

4 1.2 HCDA Bubble Energetics (T. Ginsberg; C. Moszynski, University of Delaware) l The informal report " Liquid Entrainment by an Expanding Gas or Vapor Bub-ble - A Review of Experiments and Models," BNL-NUREG-28343, was issued.

1.3 Heat Transfer in Internally Heated Pools (G.A. Greene)

A report summarizing the experiments and analysis of natural convection.

i j

heat transfer from internally heated non-boiling liquids to vertical and in-clined boundaries was completed.

j

?

i l

i I

i t

e l

1 l

l

(

r l

l L

9

'Discribution Thermal Hydraulic LMFBR Development Program s

BNL R.Cr Divisfon Heads BNL RSE Ccoup Leaders BNL RSE Personnel P. Abramson, ANL D. Basdekas, NRC J. Boudreau, LASL

1. Catton, University of California J. C. Chen, Lehigh University R. T. Curtis, NRC W. Cammill, NRC (2)

D. T. Eggen, Northwestern University H. H. Hummel, ANL (2)

W. Y. Kato, BNL M. S. Kazimi, MIT H. J. Kouts, BNL R. T. Lahey, Rensselaer Polytechnic J. T. Larkins, NRC A. Reynolds, University of Virginia M. Silberberg, NRC M. Stevenson, LASL T. C. Theofanus, Purdue University J. C. Walker, Sandia Laboratory R. W. Wright, NRC U.S. NRC Division of Technical Information and Control l