ro w snc-ssi U.S. NUCLEAR REGUL ATCRY COMMISSION t a.77)
OFFICE OF INsPUCTION AND ENFonCEMENT INSPECTION FINDINGS AND LICENSEE ACKNOWLEDGMENT
- e. LICENSEE
- a. REGaON AL or rect p7 Bethesda Lutheran Medical Center U. S. Nuclear Regulatory Corraission Office of Inspection and Enforcement 559 Capitol Blvd.
Region III 799 Roosevelt Road St. Paul, MN 55103 Glen Ellyn, IL 60137
- 3. ooCMET NUMBER (S)
- 4. LICENSE NUM B E R(S)
- 9. D ATE OF GMSPECTION 070-02881 SNM--1837 12/1&5/80
- c. IM.. PECTION FINDINGS Thz inspecuon was an esamination or the activities conducted under your license as they relate to radiasma sarcty and to compliance,with the
[
Commamn's rules and regulations and the conditions or your license. The inspection consisted of selectise examinations of procedureg and repre-sintitive tutords. interviews with personnel, and observations by the inspector. The rindings as a result of this inspntion are as rollows:
i O No items of noncompliance or unsafe conditions were found.
M-
=~
i The following items of noncompliance related to records, signs, and labels were found:
- j y;
m O
A. Rooms or areas were not properly posted to indicate the presence of a RADI ATION AREA.10Cp 20.203(.bj or 34.42.'
B. Rooms or areas were not properly posted to indicate the presence of a HIGH RADIATION AREA.
10 CFR 20.203(c)(1) or 34.42 p-O C. Rooms or areas were not properly posted to indicate the presence of an AIRBORNE RADIOACTIVITY AREA.
J s
O D. Rooms or areas were not properly posted to indicate the presence of RADIOACTIVE M ATERIAL.10 CFR 20.203(e) muum O
E. Containers were not properly labeled to indicate the presence of RADIOACTIVE M ATERI AL.
10 CFR 20.203(f)(1) or (f)(2)
O F. A current copy of 10 CFR 20, a copy of the license, or a copy of the operating procedures was not properly posted or made available.10 CFR 20.206(b)
O G. Form NRC.3 was not properly pasted.10 CFR 20.206(c) f C 11. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b)
O
- 1. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d)
O J. Records of receipt, transfer, disposal, export or inventory oflicensed material were not properly maintained.
10 CFR 30.51,40.61 or 70.51 l
C K. Records ofleak tests were not maintained as prescribed in your license, or 10 CFR 34.25(c)
L Records ofinventories were not maintamed.10 CFR 34.26 O
M. Utilization logs were not maintained.10 CFR 34.27 O
N. Records of radiation survey instrument calibration were not maintamed.10 CFR 34.24 O. Records of teletherapy electricalinterlock tests were not maintained as prescnbed in our license.
(
O P. Other
/
M E
-s
g (,
~ 44fD bert E.
urgin RhXC Insr>ector)
' The NRC Inspector has explained and I understand the items of noncompliance listed above. The items of noncompliance will be corrected within the next 30 days.
(Date)
(Lkensee Represenroti~r - Title or Position) l ORIGINAL TO LICENSEE m
F 8012190_. _