Text
N
N y
* g UNITED SrATES
?
,! ab _,, -,r NUCt. EAR REGULATORY COMMISSION I
REGICN IV k,,,'
$11 RYAN PLAZA oRIVE. SUITE 1000 ARLINGTON. TEX 4s 76011 3 0 acT so Docket No. 99900293/80-01 71uid Syst:ss Gulf and Western Manufacturing Company ACT:
Mr. R. V.
Ad" QA Manager 25 Graystone Street Waraick, Rhode Island 02886 Gentlemen:
This refers :o che QA Program. inspection conducted by Mr. J. W. Sutton of this office ;n September 30 - Oc cber 3, 1980, of your facili g a: Waraick, Rhode Island, associated with -le fabrication of Nuclear Valves and to the discussion of our findings wi h Dr. J. E. Wal:er and you at the conclusion of the inspection.
This inspec ion was nade to confirs that, in the areas inspected, your QA Program is being effectively i=plemented. The inspection efferr is not designed
- o assure : hat unique quali n requirements i= posed by a customer are being i=ple=ented; nor to assure that a specific produc, co=ponent or service provided
/
by you to your customers, is of acceptable qualig. As you know, the NRC recuires each cf 1.s licensees to assume full responsibility for the q"*'d q of specific produe:s, components or services procured from others. You should cherefore not conclude. hat.he NRC's inspeccion exe=pta you from inspections by an NRC licensee or his agents nor from :aking effective corrective action in response :o their findings.
Areas m mined during the inspection and our findd"gs are discussed in the enclosed report. Within these areas, -Je inspection consisted of an a = 4"acion of procedures and representative records, interviews with personnel, and observations by.he inspector.
Wi.hin the scope of :his inspection, we found no instance where you failed
- o neet NRC require.nents.
1
\\
8022190 ot6
Fluid Systems 2
In accordance wi:h Sec:ica 2.790 of the Oc= mission's " Rules of Practice,"
Par 2, Title 10, Code of Federal Regulations, a copy of.his letter together with the enclosed inspection repor: will be placed in :he Commission's Public Document Room.
If this report contains any information : hat you believe to be proprietary, 1: is necessary : hat you sake a written application within thirty (30) days to this office to withhold such infor: nation from public disclosure.
Any such application sust include a full statement of the reasons on the basis of which 1: is c'ad,ad that.he information is proprietary, and should be prepared so that proprietary infor: nation identified in the application is contiained in a separate part of he docu:nent.
If we do not hear irca you in
- his regard within the specified period,.he repor: will be placed in the Public Docu:nent Room.
Should you have any questions concerning this inspection, we will be plaased to discuss. hem vd:h you.
Sincerely, p-
}I
~
i L ',.)Potapovs, Chiefcm/C/1v Uldia 7endor I:spectics 3 ranch
Enclosure:
Inspeccion Report No.
99900293/80-01 i
i
., -