Summary of 800813 Meeting W/Nfs,Ny State Energy R&D Authority & Util in Silver Spring,Md Re Progress of NFS Efforts to Process Technical Decontamination & Decommissioning Data.Next Meeting Scheduled for 801015
ML19351D051
Person / Time
Site: West Valley Demonstration Project
Issue date: 08/19/1980
From: Haughney C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Rouse L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 8010080649
Download: ML19351D051 (19)


Text

!

)*o go wee fi

),

UNITED STATES f %) y g ;c, j NUCLEAR REGULATORY COMMISSION

.4 y

WASMNGTON, D. O. W555

%, "J[/

.a,ug 191980 e

Oocket No. 50-201 MEMORANDUM FOR: Leland C. Rouse, Chief Advanced Fuel and Spent Fuel Licensing Branch FROM:

Charles J. Haughney Advanced Fuel and Spent Fuel Licensing Branch

SUBJECT:

MEETING SU." MARY LICENSEES:

Nuclear Fuel Services Inc. (NFS) and New York State Energy Research and Dev'elopment Authority (NYSERDA)

(License No. CSF-1)

FACILITY:

Western New York Muclear Service Center, West Valley, New York

Purpose:

To discuss the progress of NFS efforts to process technical data useful for future decontamination and decomissioning of the West Valley facility.

Place and Date: Nuclear Regulatory Commission (NRC), Office of Nuclear Material Safety anJ Safeguards, Silver Spring, Maryland: August 13, 1980 Index of Facility Design Data The index for plant area 02, the Low Level Waste Treatment Plant, is complete.

A copy of this portion of the index is attached. The next areas to be indexed will be area 30, Electrical Distribution Facilities and area 31, Utility Room.

Report of Decontamination History Sections of the decontamination history that describe decontamination in the Pulser Equipment Aisle, the South Stainvell and the Equipment Decontamination Room have been completed as draft working papers. The final sections of the narrative portion of the report which describe decontamination in the Scrap Removal Area and in operating areas are still undergoing preparation but are expected to be con.pleted by the time of the next meeting.

I Ul0080 f

f 2-

330 Leland C. Reuse 3

Next Meeting The next meeting is tentatively scheduled for 10:30 a.m., Wednesday, October 15, 1980 at the NRC offices in Silver Spring, Maryland.

>> AA

/

h Charles J. Ha@hney Advanced Fuel and Spent uel Licensing Branch Division of Fuel Cycle and Material Safety

Enclosures:

1.

Participant List 2.

Area 02 Index - Low Level Waste Treatment Plant d

6 August 13, 1980 MEETING AMONG NFS, NYSERDA AND NYS ON WEST VALLEY DECOMMISSIONING INFORMATION

Participants:

Charles J. Haughney, NRC-FCAF Wendy Ting, NRC-FCAF James P. Duckworth, NFS-West Valley T. K. DeBoer, NYSERDA James R. Clark, NFS Neil J. Newan, NFS 1

i

UNAlT 8/80 AREA 02 - LOW LEVEL WASTE TREATMENT i

1.0 PROCESS 1.1 Dravo Orawings (Blaw-Knox) 2401-02-100-1 Material Balance Flow 01agram 2401-02-110-1 Dilute Waste Feed & Discharge 2401-02-110-2 Chemical Feed Make-up l

2401-02-110-3 Flocculation & Clarification 2401-02-110-4 Ion Exchange 2401-02-110-5 Sludge Dewatering & Drum Filling 2401-02-170-1 Utility Flow Diagram 1.2 NFS Orawings 42R-A-1089 Flow Diagram LLWT 42E-A-1100 Typical LLWT Sample Loop 2.0 LAYOUTS

]

2.1 Dravo Drawines (Blaw-Knox) 2401-02-202-1 First Floor Plan 2401-02-202-2 Second Floor Plan 2401-02-202-3 Roof Plan 2401-02-202-4 Elevation "A" 2401-02-202-5 Elevation "B" 2401-02-202-6 Elevation "C" 2401-02-202-7 Elevation "D" l

3.0 EQUIPMENT 3.1 Dravo (Blaw-Knox) 1 3.1.1 33007 Caustic Mix Tank 33007A Caustic Mix Tank Agitator Drawings 2401-02-33007-1 Caustic Mix Tank (Dravo)

J A-3862 Caustic Mix Tank (Vendor)

A-001-E-1 DimensionSheet(Vendor) 210-I.O.M.

Portable Agitator Manual (Vendor)

Soecifications 2401-V1.1 Fusion Welded Vessels Material Recuisition 2401-02-33007-R-1 Caustic Mix Tank 2401-208 Caustic Mix Tank 2401-02-33007-R-2 Agitator for Caustic Mix Tank P.O. 2401-206 Agitator for Caustic Mix Tank

DRAFT 8/80 3.1.2 33008 Ferrous Sulfate Mix Tank 33008A Agitator for Sulfate Mix Tank Drawings 2401-02-33008-1 Ferrous Sulfate Mix Tank (Dravo)

A-001-0-1 Dimension Sheet (Vendor) 210-I.O.M.

Portable Agitator Manual (Vendor)

Specifications 2401-V1.1 Fusion Welded Vessels Material Recuisitions 2401-02-33008R-1 Ferrous Sulfate Mix Tank 2401-208 Ferrous Sulfate Mix Tank 2401-02-33008R-2 Agitator for Sulfate Mix Tank P.O. 2401-206 Agitator for Sulfate Mix Tank 3.1.3 33009 Clay Slurry Mix Tank i

33009A Agitator for Clay Slurry Mix Tank Drawings 2401-02-33009-1 Clay Slurry Mix Tank (Dravo)

A-3861 Clay Slurry Mix Tank (Vendor)

A-003-C-1 DimensionSheet(Vendor) 210-I.O.M.

Portable Agitation Manual (Vendor)

Specif0 ', ion 2401-V1.1 Fusion Welded Vessels Material Recuisitions 2401-02-33009-R-1 Clay Slurry Mix Tank 2401-208 Clay Slurry Mix Tank 2401-02-33009-R-2 Agitator for Clay Slurry Mix Tank P.O. 2401-206 Agitator for Clay Slurry Mix Tank 3.1.4 33012 Recycle Mix Tank 33012A Agitator for Recycle Mix Tank Drawings 2401-02-33012 Recycle Mix Tank (Dravo)

MA-401-A-1 Dimension Sheet (Vendor) 210-I.0.M.

Portable Agitator Mixer (Vendor)

Specification 2401-V1.1 Fusion Welded Vessels

DRAFT 8/80 Material Reouisitions 2401-02-33012-R-1 Recycle Mix Tank 2401-208 Recycle Mix Tank 2401-02-33012-R-2 Agitator for Recycle Mix Tank P.O. 2401-206 Agitator for Recycle Mix Tank 3.1.5 33013 Acid Mix Tank 33013A Agitator for Acid Mix Tank Drawings 2401-02-3.013 AcidMixTank(Dravo)

A-001-B-1 Dimension Sheet (Vendor) 210-I.0.M.

Portable Mixer Manual (Vendor)

Specification 2401-V1.1 Fusion Welded Vessels Material Reouisitions 2401-02-33013-R-1 Acid Mix Tank 2401-208 Acid Mix Tank 2401-02-33013-R-2 Agitator for Acid Mix Tank P.O. 2401-206 Agitator for Acid Mix Tank 3.1.6 35105 Clarified Water Surge Tank Drawings 2401-02-35105-1 Clarified Water Surge Tank Specification 2401-V1.1 Fusion Wel.ded Vessels Material Requisitions 2401-02-35105-R-1 Clarified Water Surge Tank P.O. 2401-209 Clarified Water Surge Tank 3.1.7 41045-1 Dilute Waste Feed Pump 41045-2 Dilute Waste Feed Pump Drawinos 2401-02-110-1 Dilute Waste Feed & Discharge (Dravo) 4501-11-21-31 Sump Pump (Vendor)

. u Fig. 4521 PumpCurve(Vendor)

Fig. 7360 Pump Curve (Vendor) )

4531 Instructions (Vendor 7360 Installation & Operation (Vendor)

Soecification As stated in Requisition

pa,sT 8/80

, Material Recuisition 2401-02-41045-R-1 Dilute Waste Feed Pumps P.O. 2401-186 Oflute Waste Feed Pumps 3.1.8 41046 Caustic Metering Pump 41047 Ferrous Sulfate Metering Pump 41062 Acid Metering Pu:p Drawings 2401-02-110-2 Chemical Feed Makeup (Dravo) 2401-02-110-5 Sludge Dewatering (Vendor)& Drum Filling (Dravo)

Model No. 1731-20 Pump Dimensions Model No. 1731-23 PumpDimensions(Vendor)

Model No. 1731-13 Pump Dimensions (Vendor) 1700.44-3 Instrument Manual (Vendor)

Specification i

As stated in Requisition Material Recuisition 2401-02-41046-R-1 Metering Pumps P.O. 2401-189 Metering Pumps 3.1.9 41048*

Clay Slurry Pump I

41054 Recycle Pump 41060 Clarified Water Pump 41067-1 Ion Exchange Feed Pump 41067-2 Ion Exchange Feed Pump Drawings 2401-02-110-2 Chemical Feed Makeup (Dravo) 2401-02-110-3 Flocculation & Clarification (Da avo) 2401-02-110-5 Dewatering & Drum Filling (Drave)

PH-1085-A-3 Pur": Curve (Vendor)

PH-2200 Dimension Drawing (Vendor)

P-1200 Stuffing Box for Shaft Sealing (Vendor)

MC-1.2.34 Instruction Manual (Vendor)

PHAA-1060 Pump Curve (Vendor)

PH-2021 Dimension Drawing (Vendcr)

PHAB-1530 Pump Curve (Vendor)

PH-15100-81 Pump Curve (Vendor)

Specification As stated in Requisition Material Requisition 2401-02-41048-R-1 Centrifugal Pumps P.O. 2401-185 Centrifugal Pumps

i DRAFT 8/80 3.1.10 41066 Dilute Waste Transfer Pump Drawings 2401-02-110-1 Dilute Waste Feed & Discharge (Dravo) 2026-B Pump Curve (Vendor)

E-8202-PL Parts List (Vendor)

E-8202-6-CB Dimensions (Vendor)

E-10985-6 Bearing Bracket Asse' ly(Vendor)

Specification As stated in Requisition Material Recuisition 2401-02-41066-R-1 Dilute Waste Transfer Pump l

P.O. 2401-184 Dilute Waste Transfer Pump 3.1.11 41050 Sludge Pump The original LR6 Moyno pumo was replaced with an LR3 Moyno pump of the same style but with a smaller capacity.

Drawings j

2401-02-110-2, Chemical Feed Makeup (Dravo) l 25B MoynoPumpPartsList(Vendor) 6-3014-5 Instruction Manual (Vendor)

Specification

.i As specified in the Recuisition Material Requisition NFS-13045 Robbins & Meyers, Inc.

NFS-32821 Robbins & Meyers, Inc.

3.1.12 48070 Flocculator-Clarifier Drawings 2401-02-110-3 Flocculation & Clarification (Dravo)

MP-20256 Drive Assembly (Vendor)

MP-03811340 Wiring Diagram (Vendor) 03C12993 General Drawing (Vendor) 03D16044 Erection Drawing (Vendor) 03D16045 Tank Detail (Vendor)

MP-04D12808 Handrail Assembly (Vendor) 3550-4 Erection Instructions (Vendor) 5550 Operating Instructions (Vendor)

Specification As stated in Requisition

Drf!T 8/80 Material Recuisition 2401-02-48070-R-1 Flocculator-Clarifier P.O. 2401-96 Flocculator-Clarifier 3.1.13 48082-Instrument Air Dryer Drawings 2401-02-170-1 Utility Flow Diagram (Dravo)

A-3725 Dimension Drawing (Vendor)

E-2599 Dimension Drawing Filter (Vendor)

AIR-2 Instruction Manual (Vendor)

I Specification As specified in Requisition Material Recuisition 2401-02-48082-R-1 Instrument Air Dryer P.O. 2401-211 Instrument Air Dryer 3.1.14 48084 Caustic Feed Jet 4808S Acid Feed Jet

' Drawings 2401-02-110-2 Chemical Feed Makeup (Dravo)

SIA-106810 Special Bar Stock Ejectors (Vendor)

Specification As specified in the Requisition Material Reouisition 2401-02-48084-R-1 Chemical Feed Jets P.O. 2401-199 Chemical Feed Jets 3.1.15 48090 Centrifuge Drawings 2401-02-110-5 Dewatering & Drum Filling (Dravo)

Dimensions (Vendor)g (Vendor)

Installation Drawin 01012905 Podel DP-1 Section 245 Motor Dimensions (Vendor)

DF-1-3A -

Parts List (Vendor)

Specification As specified in the Requisition Material Reouisition 2401-02 48090-R-1 Sludoe Centrifuge P.O. 2401-97 Sludge Centrifuge

DRAFT 8/80 1 3.1.16 48092-1 Ion Exchanger 48092-2 Ion Exchanger Drawings 2401-02-110-4 Ion Exchange (Dravo)

X-6-000-94 Exchange Tank Detail (Vendor)

A-6-100-75 Assembly Upper Distributor (Vendor)

S0-5914 Internal Installation (Vendor)

A-6-110-69 Regenerant Distributor (Vendor)

A-6-120-62 Stainless Steel "U" Drain (Vendor)

ARC-359 Backwash Flowrate (Vendor)

Specification As specified in Requisition Material Recuisition 2401-02-48092-R-1 Ion Exchangers P.O. 2401-191 Ion Exchangers 2401-02-48092-R-2 Ion Exchange Resin 1

P.O. 2401-282 Ian Exchange Resin 3.1.17 48091 Clarified Water Filter Drawings 2401-02-110-3 Flocculation & Clarification (Dravo) 7290001 General Arrangement (Vendor) 72900D200 General Arrangement (Vendor) 72900D201 General Arrangement (Vendor) 17942 "8" Tee Assembly (Vendor) 72900C12 Wiring Details (Vendor) 4-7880 29810 Air Cylinder (Vendor) 8345 4-Way Solenoid Valve (Vendor)

SVG-10-2 Installation, Operation Manual (Vendor)

Specification As specified in the Requisition Material Reouisition 2401-02-48001-R-1 Clarified Water Filter P.O. 2401-98 Clarified Water Filter 3.1.18 48096 Inline Mixer Drawings 2401-02-110-4 Ion Exchange (Dravo) 37-56-065 Static Mixer System (Vendor) i Specification As specified in the Requisition 1

ORAFT 8/80 Material Recuisition 2401-02-48096-R-1 Inline Mixer P.O. 2401-219 Inline Mixer 3.1.19 48098 Shielding Window 48099

" Shielding Window Drawings D-5075-01 ShieldingWindow(Vendor) 0-5075-02 Shielding Window (Vendor)

Specification As specified in Requisition Material Recuisition 2401-02-48098-R-1 Shielding Window P.O. 2401-236 Shielding Window 3.1.20 48102 Waste Treatment Chemical Hoist Drawings 510-WFC-250 Wire Rope Electric Hoist (Vendor) 599-WFC-376 Cable Reel (Vendor) 6429523 Wiring Diagram (Vendor) 165245001 General Instructions (Vendor) 165172001 Instruction & Parts Manual (Vendor)

Specification As specified in Requisition Material Recuisition 2401-02-48102-R-1 Waste Treatment Chemical Hoist P.O. 2401-200 Waste Treatment Chemical Hoist 3.1.21 48103 Additive Mixer Drawings 2401-02-110-3 Flocculation & Clarification (Dravo) 03-870-0074-3 Outline Dimension Sheet (Vendor) 270-21795 Mixer Model FDLS-34 (Vendor)

Specification As specified in Requisition Material Recuisition 2401-02-48103-R-1 Inline Mixer P.O. 2401-242 Inline Mixer

GRAG o/ ou 3.1.22 48121 Drum Feed Conveyor 48122 Drum Filling Conveyor 48123 Drum Discharge Conveyor Drawings 2401-02-110-5 Dewatering & Drum Filling (Dravo) 2401-02-48121-2 Conveyor Switch Detail 2401-02-48121-3 Conveyor Switch Detail l

91409 Installation, Maintenance & Lube (Vendor) i SQ61-5 SQAIR Cylinders (Vendor)

Specification As specified in Requisition Material Recuisition l

2401-02-48121-R-1 Drum Conveyors P.O. 2401-268 Drum Conveyors 3.1.23 50043 Shielding Door Drawings 2401-02-50043-1 Shielding Door Arranaement (Dravo) 2401-02-50043-2 Shielding Door Details (Dravo) 2401-02-50043-3 Shielding Door Details (Dravo) 56679 Parts Manual (Vendor)

X-1127 Automatic Safety Clutch (Vendor) 10429-50043-1 Shielding Door Arrangement (Vendor) 10429-50043-2 Shielding Door Details (Vendor) 10429-50043-3 Shielding Door Details (Verdor)

Specification 2401-01.1 Machine Design Specification Material Recuisition 2401-02-50043-R-1 Shielding Door P.O. 2401-269 Shielding Door 3.1.24 50044 Sludge Drum Transport Cask Drawings 2401-02-50044-1 Drum Transport Coffin Arrangement (Dravo) 2401-02-50044-2 Drum Transport Coffin Details (Dravo) 2401-02-50044-3 Drum Transport Coffin Details (Dravo) 2401-02-50044-4 Drum Transport Coffin Details (Dravo) 2401-02-50044-5 Drum fransport Coffin Details (Dravo) 10436-50044-1 Transport Coffin Arrangement (Vendor) 10436-50044-2 Transoort Coffin Details (Vendor 10436-50044-3 Transport Coffin Details (Vendor 10436-50044 4 Transport Coffin Details (Vendor 10436-50044-5 Transport Coffin Details (Vendor)

o ORAFT 8/80 Specification 2401-01.1 Machine Design Specification Material Recuisition 2401-02-50044-R-1. Drum Transport Coffin P.O. 2401-269 Drum Transport Coffin 2401-02-50044-R-2 Truck for Drum i

3.1.25 50046 Drum Ltd Loading Station Drawines 2401-02-50046-1 Drum Lid Loading Station (Dravo) 2401-02-50046-1 Lid Loading Station (Vendor)

Specification 2401-01.1 Machine Design Specification Material Requisition 2401-02-50046-R-1 Drum Lid Loading Station P.O. 2401-270 Drum Lid Loading Station 2401-02-50046-R-2 Drum Loading Staticn Air Cylinder P.O. 2401-323 Drum Loading Station Air Cylinder 3.1.26 50047 Orum Lid Clamping Station Drawings 2401-02-50047-1 Drum Lid Clamping Station Arrangement (Dravo) 2401-02-50047-2 Drum Lid Clamping Station Details (Dravo) 2401-02-50047-2A Orum Lid Modification Details (Dravo) 2401-02-50047-3 Drum Ltd Clamping Station Details (Dravo) 2401-02-50047-4 Drum Ltd Clamping Station Details (Dravo 2401-02-50047-5 Drum Lid Clamping Station Details (Dravo 2401-02-50047-6 Drum Lid Clampirg Station Details (Dravo 2401-02-50047-7 Drum Lid Clamping Station Details (Dravo VLWF113Y-101 Outline Drawing (Vendor)

VLWF113Y-102 Data Assembly (Vendor) 10437-50047-1 ClampingStationArrangement(Vendor) 10437-50047-2 ClampingStationDetails(Vendor) 10437-50047-3 Clamping Station Details -(Vendor) 10437-50047-4 Clamoing Station Details (Vendor) 10437-50047-5 Clamping Station Details (Vendor)

Specification 2401-01.1 Machine Design Specification Material Requisitions 2401-02-50047-R-1 Drum Lid Clamping Station P.O. 2401-292 Drum Lid Clamping Station l

~

DRAFT 8/80 2401-02-50047-R-2 Clamping Station Air Valves P.O. 2401-327 Clamping Station Air Valves 2401-02-50047-R-3 Clamping Station Air Valve P.O. 2401-322 Clamoing Station Air Valve 2401-02-50047-R-4 Air Hose for Drum Filling Line P.O. 2401-324 Air Hose for Drum Filling Line 2401-02-50047-R-5 Drum Lid Closing Ring P.O. 2401-337 Drum Ltd Closing Ring 3.1.27 50048 Drum Filling Station Drawings 2401-02-50048-1 Drum Filling Station Arrangement (Dravo) 2401-02-50048-2 Drum Filling Station Details (Dravo) 2401-02-50048-3 Drum Filling Station Details (Dravo) 2401-02-50048-4 Drum Filling Station Detafis (Dravo) 2401-02-50048-5 Drum Filling Station Details (Dravo) 10435-50048-1 Filling Station Arrangement (Vendor) 10435-50048-2 Filling Station Details (Vendor) 10435-50048-3 Filling Station Details (Vendor)

Specification 2401-01.1 Machine Design Specification Material Recuisition 2401-02-50048-R-1 Drum Filling Station 3.1.28 50051 Impact Wrench & Liner Drawings 2401-02-50051-1 Impact Wrench & Lin::r Arrangement (Dravo)

HA-320-50051-1 ImpactWrenchArrangement(Vendor)

Specification As stated in Requisition Material Requisition 2401-02-50051-E-1 Impact Wrench & Liner P.O. 2401-310 lanct Wrench & Liner 3.2 NFS 3.2.1 35154 Acid Storage Tank Drawings 2401-02-110-4 Ion Exchange (Dravo)

B-22730 3008 Gallon Tank (Vendor) 42 B-D-1053 Sulfuric Acid Storage Tank (NFS)

f DRAFT l

8/80 Specification As stated on Purchase Documents Material Requisitions NFS Req. 10509 3008 Gallon Tank NFS P.O. 29054 3008 Gallon Tank 3.3 General 3.3.1 Drawings 42 0-L-1047 EFD - H SO Regen. Area (NFS) 2 4 3.4 Heating and Ventilating l

3.4.1 Drawings 2401-02-400-1 Title Page (Dravo) 2401-02-400-2 Systems & Control Diagram (Dravo) 2401-02-400-3 Control Diagrams (Dravo) 2401-02-402-1 Plans (Dravo) 2401-02-402-2 Sections and Details (Dravo) 2401-02-402-3 Roof Plan Sections & Details (Dravo) 3.4.2 Specifications 2401-02-H-1 Heating & Ventilation 2401-02-H-2 Sheet Metal Work 3.4.3 Material Reouisitions 2401-02-471-R-11 Indirect Fired H&V Unit P.O. 2401-216 Indirect Fired H&V Unit 2401-02-474-R-6 Louvers P.O. 2401-214 Louvers 2401-02-475-R-5 Exhaust Fans P.O. 2401-213 Exnaust Fans 2401-02-478-R-5 Sheet Metal Work P.O. 2401-276SC Sheet Metal Work 2401-02-479-R-14 Supply Air Intake Filter P.O. 2401-225 Supply Air Intake Filter 2401-02-479-R-15 Filter Enclosures P.O. 2401-217 Filter Enclosures 2401-02-479-R-16 Dampers P.O. 2401-212 Dampers 3.5 Instrumentation 3.5.1 Drawings 2401-600-8 Inst. Panel Piping & Wiring (Dravo) 2401-02-610-11 Tubing Routing First Floor (Dravo) 2401-02-610-12 Tubing Routing Second Floor (Dravo) 2401-02-680-12 Installation Details (Drava) 2401-02-680-16 Installation Details (Dravo)

DRAFT 8/80 3.5.2 Specification i

2401-02-C6 Instrument Item List 3.5.3 Requisitions 2401-02-600-22 Instrument Panels P.O. 2401-201 Instrument Panels 2401-02-601-R,3 Miniature Receivers l

P.O. 2401-194 Miniature Receivers i

2401-02-604-R-2 Annunciator P.O. 2401-195 Annunciator 2401-02-607-R-8 Manual Loaders P.O. 2401-193 Manual Loaders J

2401-02-607-R-10 Timer P.0, 2401-203 Timer 2401-02-507-R-11 Solenoid Yalve P.O. 2401-204 Solenoid Valve 2401-02-615-R-1 Temperature Switch P.O. 2401-280 Tenperature Switch 2401-02-620-R-1 Pressure Indicator Controller P.O. 2401-265 Pressure Indicator Controller 2401-02-624-R-4 Pressure Indicating Gages P.O. 2401-346 Pressure Indicating Gages 2401-02-625-R-2 Pressure Switches P.O. 2401-347 Pressure Switches 2401-02/17-628-R-3 Relief Valves l

P.O. 2401-279 Relief Valves 2401-02-634-R-2 Rotameters P.O. 2401-248 Rotameters 2401-02-637-R-3 Orifice Plate Assembly P.O. 2401-238 Orifice Plate Assembly 2401-02-648-R-1 Gage Glasses P.O. 2401-247 Gage Glasses 2401-02-650-R-5 Differential Pressure Transmitters P.O. 2401-205 Differential Pressure Transmitters 2401-02-650-R-6 Differential Pressure Transmitters P.O. 2401-264 Differential Pressure Transmitters 2401-02-652-R-2 Receiver Gages P.O. 2401-284 Receiver Gages 2401-02-660-R-7 Control Valve P.O. 2401-188 Control Valve 2401-02-660-R-8 Control Valve P.9. 2401-248 Control Valve 2401-02-660-R-9 Diaphragm Valves P.O. 2401-309 Diaphragm Valves 2401-02-670-R-1 Potentiometer Recording Controller P.O. 2401-182 Potentiometer Recording Controller 2401-02-670-R-2 pH Electrode Assembly P.O. 2401-183 pH Electrode Assembly 2401-02-691-R-3 Valves Piping P.O. 2401-320 Valves Piping 2401-02-694-R-3 Purge Units P.O. 2401-285 Purge Units

B DRAFT 8/80 2401-02-696-R-1 Instrument Valves P.O. 2401-285 Instrument Valves 2401-02-697-R-1 Air Sampling System P.O. 2401-312 Air Sampling System 2401-02-622-R-4 Pressure Regulators.

P.O. 2401-301 Pressure Regulators 3.6 Piping 3.6.1 Drawings 2401-02-702-2 Underslab Piping Plan (Dravo) 2401-02-702-3 Underslab Piping Details (Dravo) 2401-02-702-4 Underslab Piping Detafis (Dravo) 2401-02-702-7 Piping - Exterior Wall Pene. (Dravo) 2401-02-702-8 Piping Interior Wall Pene. (Dravo) 2401-02-702-9 Piping - Shielding for 02 AR-1E (Dravo) 2401-02-702-101 Isometric, General Notes (Dravo) 2401-02-702-102 Section, Through Back (Dravo) j 2401-02-702-201 Thru -257 SS Fabrication (Dravo) 2401-02-702-301 Thru -353 Carbon Steel Fab (Dravo) 3.6.2 Soecifications 2401-00-P1 Piping Materials 2401-00-P1A Piping Material Description 2401-00-P2A Piping Fab. & Installation 2401-00-P2D Field Handling Underground Pipe 2401-00-P2F Testing & Cleaning 2401-00-P2G Protective Coatings 2401-00-P5 Piping Line Index' 2401-00-P2C.

Piping Design & Arrangement 3.6.3 Material Recuisition 2401-02-700P R200 Thru R234 Piping Material Requisitions Requisitions for piping material were written in accordance with Spec. 301-00 Pl.

3.7 Struciural & Architecturz.1 3.7.1 Drawings 2401-02-802-1 Foundation Plan - Sect. & Detail (Dravo) 2401-02-802-2 Elevations & Details (Dravo) 2401-02-802-3 Sump Plan, Sect. & Details (Dravo) 2401-02-802-4 Vessel Foundations (Dravo) 2401-02-802-6 Ground Floor Slab, Plan (Dravo) 2401-02-802-7 Sections & Details (Dravo) 2401-02-802-8 Second Floor & Roofing, Plan (Dravo-)

l 2401-02-802-9 Elevation & Details (Dravo) 2401-02-802-10 Plan Section & Details (Dravo) 1 2401-02-802-11 Sections (Dravo)

DRAFT 8/80 1 2401-02-802-13 Second Floor Slab, Sections (Oravo) 2401-02-802-14 Sections & Details (Dravo) 3 2401-02-802-15 Sections & Details (Oravo) 2401-02-802-16 Reinforcing Plan & Sections (Dravo) 2401-02-802-17 Lagoons #4 & 5 Plan & Sections (Dravo) 2401-02-802-18

  • Support for 02 AR-1E (Dravo) 2401-02-802-51 First Flocr Plan (Dravo) 2401-02-802-52 Second Floor & Roof Plan (Dravo) 2401-02-802-53 Building Sections (Dravo) 2401-02-802-54 Elevations (Dravo) 2401-02-802-55 Door Schedule (Dravo) 3.7.2 Specifications 2401-R4.01 Concrete Masonery 2401-RS.21 Steel Deck Roof 2401-R7.41 Sheet Metal Work 2401-R8.11 Hollow Metal Doors 2401-R8.21 Finish Hardware 2401-R9.71 Field Painting 2401-T2.31 Site Grading 2401-T2.34 Excav. Filling & Back Filling - Structures 2401-T2.35 Excav. Filling & Back Filling - Utilities 2401-T2.51 Roads & Paved Areas 2401-T2.71 Finish Grading 3.7.3 Material Recuisitions 2401-02-800-R-6 Concrete Masonery P.O. 2401-231 Concrete Masonery 2401-02-802-R-1 Hollow Metal Doors P.O. 2401-171 Hollow Metal Doors 2401-02-802-R-2 Steel Decking P.O. 2401-180 Steel Decking 2401-02-802-R-3 Built Up Roof P.O. 2401-293SC Built Up Roof 2401-02-802-R-4 Roll Up Door P.O. 2401-308 Roll Up Door 2401-02-802-R-7 Graded Silica Aggregate P.O. 2401-357 Graded Silica Aggregate 2401-02-8025-R-1 Structural & Miscellaneous P.O. 2401-133 Structural & Miscellaneous 3.8 Electrical 3.8.1 Drawinos.

Standard S cbols (Dravo) 2401-02-900-1 3

2401-02-900-2 Standard Grounding (Dravo) 2401-02-902-1 Plot Plan (Dravo) 2401-02-902-2 Signal Lines Diagram (Dravo) 2401-02-902-3 MCC #11 General Notes (Dravo) 2401-02-902-4 Plan, First Floor (Dravo) 2401-02-902-5 Plan, Second Floor (Dravo)

DRAFT 8/80 4 2401-02-902-6 Power & Communications (Dravo) 2401-02-902-7 Sections & Details (Dravo) 2401-02-902-8 Details (Dravo) 2401-02-902-9 Wiring Otagrams (Dravo) 2401-02-902-10 Wiring Diagrams (Dravo) 2401-02-902-11 Inst. One Line & Misc. Diag. (Dravo) 2401-02-902-12 Equipnent List (Dravo) 2401-02-902-13 Drum Handling System (Oravo) 2401-02-902-14 Heat Tracing (Dravo) 2401-02-902-15 Drum Handling Connections (Dravo) 2401-02-902-16 Drum Handling Connections (Dravo) 3.8.2 Soecification As specified in Requisitions 1

3.8.3 Material Requisitions 2401-02-902-R-1 Motor Control Center P.O. 2401-210 Motor Control Center

)

2401-02-902-R-10 Electrical Installation P.O. 2401-272SC Electrical Installation 4