ML19351C976

From kanterella
Jump to navigation Jump to search
Forwards LER 80-044/03X-1
Date released: 12/31/2019 Download: ML19351C976


LER 80-044/03X-1:on 800701,0702 & 0902 Safety Injection Tanks (SIT) Were Found W/Boron Concentrations Below Tech Spec Limit.Caused by Failure to Flush Fill Line After Shutdown Cooling & Before SIT Makeup Injection
ML19351C977
Person / Time
Site: Arkansas Nuclear 
Issue date: 10/01/1980
From: Matthew Smith
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19351C977 (4)
Forwards LER 80-044/03X-1
ML19351C975
Person / Time
Site: Arkansas Nuclear 
Issue date: 10/01/1980
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19351C975 (1)