Text
' tic, 7
C3
[4 atc,o, u
UNITED STATES NUCLEAR REGULATORY COMMISSION 3 ' *-) # I REGION IV U !
S 611 RYAN PLAZA DRIVE, SUITE 1000
~.
E ARLINGTON, TEXAS 76012 NM[
21 AUG 1980 Docket No. 99900251/80-02 Joseph Oat Corporation Attn:
Mr. Maurice Holtz President
)
2500 Broadway Camden, New Jersey 08104 Gentlemen:
1 This refers to the QA Program inspection conducted by Mr. Ross L. Brown of this office on July 28 - August 1,1980, of your facility at Camden, New Jersey
-i associated with the manufacture of heat exchangers and to the discussion of our fuiings with Mr. Martin Kaplan and members of your staff at the conclusion of ta inspection.
This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services proct.rau Som others.
You should therefore not conclude that the NRC's inspection exempts you f. rom inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.
Areas examined during the inspection and our fin' dings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination q
of procedures and representative records, interviews with personnel, and observations by the inspector.
'Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.
8010080l#$
Joseph Oat Corporation 2
In accordance with Section 2.790 of the Commission's " Rules of Practice,"
Part 2 Title 10, Code of Federal Regulations, a copy of this letter together with the enclosed inspection report will be placed in the Commission's Public Document Room.
If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure.
Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that the proprietary information identified in the application is contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, boy?
Uldis Potapovs, Chief, Vendor Inspection Branch
Enclosure:
Inspection Report No. 99900251/80-02
.