ML19350F147

From kanterella
Jump to navigation Jump to search
Forwards LER 81-034/03L-0
Date released: 12/30/2019 Download: ML19350F147


LER 81-034/03L-0:on 810602,during Testing,Control Rod Driveline J-3 Overtravel Alarm Came Up & Rod Position Indication Was Lost.Probably Caused by Detached Inner filter.J-3 Recoupled
ML19350F148
Person / Time
Site: Dresden 
Issue date: 06/10/1981
From: Holland P
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19350F148 (1)
Forwards LER 81-034/03L-0
ML19350F146
Person / Time
Site: Dresden 
Issue date: 06/10/1981
From: Scott D
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19350F146 (1)